Henny Penny EEG-143 Modifying Product Settings, To Change Times and Temperatures, Cook ID Change

Page 55

5-1. MODIFYING PRODUCT SETTINGS (Continued)

609

Model EEG-141, 142, 143, 144

To Change Times and Temperatures

7. Press button until “COOK TIME” shows in the display, and then use the product buttons, or the and buttons, to change the time in minutes and seconds, to a maximum of 59:59.

8.Press button and “TEMP” shows in the display, along with the preset temperature on the right side of the display.

Press the product buttons, or the and buttons, to change the temperature. The temperature range is 190°F (88°C) to 375°F (191°C).

Cook ID Change

9.Press button until “COOK ID” shows in the display along with the product ID. For example, NUG would be the

ID for nuggets. Use the product buttons, or the and buttons, to change the ID.

Alarms (1 & 2)

11. Press button until “ALRM 1” shows in the left display, and an alarm time in the right display. Press the product buttons,

or the and buttons, to set an alarm.

Ex., If a Cook Cycle was set at 3 minutes, and an alarm was to go off after 30 seconds into the Cook Cycle, “2:30” would be set in the display at this time. When the timer counts down to 2:30 the alarm sounds.

After the alarm time is set, press button and “ALRM 2” shows in the display, and a second alarm can be programmed.

Quality Timer (hold time)

12. Press button until “QUAL TMR” shows in the display along with the preset holding time. Press the product buttons,

or the and buttons,to adjust holding time, up to 59:59.

GlobalIncludeFinlterFilterTrackingCount

13a. Press button until “INCL IN FLTR CNT” flashes in the display along with “YES” or “NO”. Using and buttons, change the display to “YES” if that product’s Cook Cycles are to be counted as part of the recommended filter process. Set to “NO” if it is not to be included.

5-2

Image 55
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Introduction FeaturesProper Care Assistance SafetySafety Page Unpacking InstallationSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Motor Bearings Lightingand Shutdown of the Burners Electrical RequirementsDimensions Page Refer to explanations on the next pages Operation Operating ComponentsDescription Operating ComponentsFunction Description Function JIB VAT Type Full or Split SET-UP ModeFill POT from Bulk Filling or Adding OILMorning START-UP Procedures Basic Operation Idle Mode Selectinga Product Withadifferent Setpoint Replacing the JIB OIL Guardian Auto Top-OffFilling Oil Reservoir Removing/Cleaning ReservoirModel EEG-141 OIL ReservoirSmartfilter Express Smartfilter Express Filter ErrorCheck Filter Pan a new filter pad should be used on Daily FilteringDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT CLEAN-OUT ModeCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Filter Button Stats Actual Oil TemperatureRecovery Information for each Vat Info Button StatsProcedureFrequency Preventive Maintenance ScheduleClean Blower & Vents Page Information Mode Details Information ModeFunction Display EX DetailsTUE NEW OIL Reset usage data Change Product Names Product Program Mode Modifying Product SettingsAssign Button Quality Timer hold time Modifying Product SettingsTo Change Times and Temperatures Alarms 1MixFilterdAfterFil TrackingX Number of Loads Filter Control Level 2 Programming Special Program ModeLanguage SP-2 Special Program ModeAudio Volume SP-4 Degrees Fahrenheit or Celsius SP-1Audio Tone SP-5 Idle Mode Enabled SP-7Liquid or Solid Cooking Oil Used SP-6 Mixed Filter Tracking Mode SP-8If Global is selected, press button GlobalPolish Duration SP-9 Clean-Out Time SP-11Clean-Out Temperature SP-12 Cooking Indicator SP-15Fryer Type SP-19 2nd Volume SP-17Engery Save Mode SP-18 2nd Language SP-16Serial Number Log SP-24 Autolift Enabled SP-21Bulk Oil Supply SP-22 Bulk Oil Disposal SP-23Let User Exit Fill SP-29 Usage Code Change SP-26Dispose Requires Code ? SP-27 Longer Fill Time SP-28Model EEG-141, 142, 143 Problem Cause Correction Troubleshooting Trouble Shooting GuideRemove the right side panel Display Cause Correction Error CodesClosed Error Codes Display Cause CorrectionPage Henny Penny Corporation Box Eaton,OH Toll free in USA