Model EEG-141, 142, 143, 144
SECTION 7. TROUBLESHOOTING
7-1. TROUBLE SHOOTING GUIDE
|
|
|
Problem | Cause | Correction |
POWER switch ON but | • Open circuit | • Plug fryer in |
fryer completely inoperative |
|
|
|
| • Check breaker or fuse at supply box |
Control error code | • Oil temperature too high | • Press the red reset button under the right |
|
| side of the controls; if high limit does not |
|
| reset, high limit must be replaced |
Vat is
•JIB is low or empty
•JIB oil line is clogged or collapsed
•Filter pan needs cleaned
•Fill the JIB
•Check JIB line
•Clean filter pan and change paper or pad
609 |