3-7. OIL GUARDIAN™ (Auto Top-Off)
3-8. SELECTINGA PRODUCT
WITHADIFFERENT SETPOINT
3-9. REPLACING THE JIB
Figure 1
Model EEG-141, 142, 143, 144
During normal operation, the control automatically monitors the oil level in the vat. If the control senses the oil level too low, the unit automatically pumps oil from the JIB into the vat to keep the oil at the proper level.
Manual Top-Off
If the oil level is a little low, oil can be added to the vat at any time from the JIB to raise the oil level to the proper level by following the steps below. This procedure is NOT to be used to fill an empty vat
1. | Press and hold | ||
| “*FILTER MENU*”, along with “1.EXPRESS FILTER”. | ||
2. | Press | 5 times until “6.FILL FROM JIB” shows in | |
| the display. |
|
|
3.Press √ button and display shows “*PUMP” and “EXIT”.
4.Press and hold √ button and display shows “FILLING” and the oil is pumped from the JIB to the vat.
5.Once frypot is full, release √ buttonX and display returns to “*PUMP” and “EXIT”. Press button twice to return to normal operation.
When selecting a product, if “XXX XXX” shows in the display, the setpoint temperature is not correct for this product.
To change the setpoint temperature for the desired product:
1.Press product button, for ex: (FRY).
2.Display shows “XXX XXX”.
3. | Press and hold a timer button | or | for 5 |
| seconds and then “FRY” shows in display. |
|
4.Allow oil temperature to reach setpoint temperature before dropping product.
1.Control displays “JIB IS LOW” and an alarm sounds.
2.Open right door and pull JIB from unit. Pull the cap from top of JIB and discard empty JIB and replace with full one. Figure 1
Model
510