Henny Penny EEG-144, EEG-142, EEG-141, EEG-143 warranty SET-UP Mode, VAT Type Full or Split

Page 26

 

Model EEG-141, 142, 143, 144

3-2. SET-UP MODE

Upon initial start-up, the controls will ask to confirm the settings for

 

the fryer.

When the main power switch is turned on, “OFF” shows in both

displays. Press on either side and *SETUP* *ENTER CODE* shows in the displays. Press 1, 2, 3, and “LANGUAGE” shows on the left display, “ENGLISH” on the right display.

Use or buttons to change the operation display to, “FRANCAIS”, “ESPANOL”, “PORTUG”, “DEUTSCHE”, “SVENSKI”, “RUSSIAN”.

Press

to continue with the other set-up items which include:

TEMP FORMAT - oF or oC

TIME FORMAT - 12-HR or 24-HR

ENTER TIME - Time of day (use product buttons to change)

ENTER TIME - AM or PM

DATE FORMAT - MM-DD-YY or DD-MM-YY

ENTER DATE - Today’s date (use product buttons to change)

DAYLIGHT SAVING TIME - 1.OFF; 2.US (2007 & after); 3.EURO; 4.FSA (US before 2007)

FRYER TYPE - ELEC or GAS

VAT TYPE - FULL OR SPLIT

AUTOLIFT ENABLED? - NO LIFT or YES LIFT

BULK OIL SUPPLY - YES or NO

BULK OIL DISPOSE? - YES or NO

S/N - Shows serial number of the unit or can be recorded (THIS

SERIAL NUMBER SHOULD MATCH THE SERIAL NUMBER ON THE DATA PLATE, ON THE DOORS.)

2nd LANGUAGE - By setting a second language in the controls,

2 languages can now be easily chosen by pressing during normal operation.

One language shows in the left display and the second language shows in the right display. Pressing the √ button under the desired language, selects that language seen in displays.

• 2nd VOLUME - By setting a second volume in the controls,

2 volumes can now be easily chosen by pressing twice during normal operation.

One volume setting shows in the left display (NONE to 10; 10 being the loudest) and the second volume shows in the right display. To select the volume, press the √ button under the desired volume .

• SETUP COMPLETE

Unless otherwise indicated, use or to change settings.

The Setup Mode can also be accessed by re-initializing the controls, in Special Program Mode, in Level 2 programming (SP-3).

3-5

809

Image 26
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Proper Care FeaturesIntroduction Safety AssistanceSafety Page Installation UnpackingSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Electrical Requirements Motor Bearings Lightingand Shutdown of the BurnersDimensions Page Operation Operating Components Refer to explanations on the next pagesFunction Operating ComponentsDescription Description Function JIB SET-UP Mode VAT Type Full or SplitFilling or Adding OIL Fill POT from BulkMorning START-UP Procedures Basic Operation Idle Mode OIL Guardian Auto Top-Off Selectinga Product Withadifferent Setpoint Replacing the JIBReservoir Removing/Cleaning ReservoirModel EEG-141 OIL Filling Oil ReservoirSmartfilter Express Filter Error Smartfilter ExpressDaily Filtering Check Filter Pan a new filter pad should be used onDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT Mode CLEAN-OUTCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Info Button Stats Actual Oil TemperatureRecovery Information for each Vat Filter Button StatsPreventive Maintenance Schedule ProcedureFrequencyClean Blower & Vents Page Information Mode Information Mode DetailsDetails Function Display EXTUE NEW OIL Reset usage data Assign Button Product Program Mode Modifying Product SettingsChange Product Names Alarms 1 Modifying Product SettingsTo Change Times and Temperatures Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Level 2 Programming Special Program Mode Filter ControlDegrees Fahrenheit or Celsius SP-1 Special Program ModeAudio Volume SP-4 Language SP-2Liquid or Solid Cooking Oil Used SP-6 Idle Mode Enabled SP-7Audio Tone SP-5 Filter Tracking Mode SP-8 MixedGlobal If Global is selected, press buttonCooking Indicator SP-15 Clean-Out Time SP-11Clean-Out Temperature SP-12 Polish Duration SP-92nd Language SP-16 2nd Volume SP-17Engery Save Mode SP-18 Fryer Type SP-19Bulk Oil Disposal SP-23 Autolift Enabled SP-21Bulk Oil Supply SP-22 Serial Number Log SP-24Longer Fill Time SP-28 Usage Code Change SP-26Dispose Requires Code ? SP-27 Let User Exit Fill SP-29Model EEG-141, 142, 143 Troubleshooting Trouble Shooting Guide Problem Cause CorrectionRemove the right side panel Error Codes Display Cause CorrectionError Codes Display Cause Correction ClosedPage Henny Penny Corporation Box Eaton,OH Toll free in USA