| Model | |
| In the event of a control system failure, the digital display shows an | ||
|
| error message. The message codes are shown in the DISPLAY | |
|
| column below. A constant tone is heard when an error code is | |
|
| displayed, and to silence this tone, press any button. | |
|
|
|
|
DISPLAY | CAUSE | CORRECTION | |
|
|
|
|
• Control board | • Turn switch to OFF position, then turn switch back to ON; | ||
| overheating | if display shows | |
|
| check the louvers on each side of the unit for obstructions | |
|
|
|
|
• Oil overheating | • Turn switch to OFF position, then turn switch back to ON; | ||
|
| if display shows | |
|
| probe should be checked | |
|
|
|
|
• Temperature | • Turn switch to OFF position, then turn switch back to ON; | ||
| probe open | if display shows | |
|
| checked |
|
• Temperature | • Turn switch to OFF position, then turn switch back to ON; | ||
| probe shorted | if display shows | |
|
| checked |
|
•Highlimit | • Press the red reset button under the right side of the controls; | ||
|
| if high limit does not reset, high limit must be replaced |
Drain switch | Make sure drain knob is completely | |
|
| have drain switch checked |
|
|
|
• Left level sensor open | • Turn switch to OFF position, then turn switch back to ON; if | |
• Right level sensor open | display still indicates a failed sensor, have the connectors | |
• Both level sensors open | checked at the control board; have sensor checked & replace if | |
|
| necessory |
|
|
|
809 |
|