Henny Penny EEG-141, EEG-142, EEG-144, EEG-143 warranty Basic Operation Idle Mode

Page 29

3-5. BASIC OPERATION

3-6. IDLE MODE

809

Model EEG-141, 142, 143, 144

1.Once out of the Melt Cycle, LOW TEMP flashes until the set- point temperature has been reached. Once the set-point temperature has been reached, the product name now shows in the display, ex: FRY, and product now can be placed in the oil.

2. Press a timer button

or

.

3.Display shows the name of the product cooking(ex: “FRY”) and the timer counting down.

4.When cook cycle is complete, and alarm sounds and display shows “DONE”.

5.Press the timer button under “DONE” to stop the alarm, and lift basket from vat.

6.If a Quality Timer (hold timer) has been programmed, the hold time starts automatically when the user presses the timer button to end the cook cycle. While the quality timer counts down, the display shows the three-digit product abbreviation followed by “Qn”, where “n” is the number of minutes remaining.

ex: “FRY” / “Q5” / “FRY” / “Q5” / “FRY” / “Q4”, etc.

At the end of the timer countdown, the control beeps and the display shows “QUAL” followed by the three-digit product name: “QUAL” / “FRY” / “QUAL”/ “FRY”. Press the timer button to cancel the timer.

To stop a cook cycle at any time, press and hold the timer

button or .

Once programmed, the Idle Mode help saves on oil and utility costs by lowering the set-point of the oil when the vat is not being used. To activate the Idle Mode, press the button, or can be programmed to activate automatically after “X” minutes of inactivity on the vat.

The oil is maintained at a lower temperature until the button is pressed, and then the oil is heated to cooking temperature. See Special Program Modes, SP-12, SP-13 & SP-14.

3-8

Image 29
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Proper Care FeaturesIntroduction Assistance SafetySafety Page Unpacking InstallationSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Motor Bearings Lightingand Shutdown of the Burners Electrical RequirementsDimensions Page Refer to explanations on the next pages Operation Operating ComponentsFunction Operating ComponentsDescription Description Function JIB VAT Type Full or Split SET-UP ModeFill POT from Bulk Filling or Adding OILMorning START-UP Procedures Basic Operation Idle Mode Selectinga Product Withadifferent Setpoint Replacing the JIB OIL Guardian Auto Top-OffModel EEG-141 OIL Removing/Cleaning ReservoirReservoir Filling Oil ReservoirSmartfilter Express Smartfilter Express Filter ErrorCheck Filter Pan a new filter pad should be used on Daily FilteringDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT CLEAN-OUT ModeCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Recovery Information for each Vat Actual Oil TemperatureInfo Button Stats Filter Button StatsProcedureFrequency Preventive Maintenance ScheduleClean Blower & Vents Page Information Mode Details Information ModeFunction Display EX DetailsTUE NEW OIL Reset usage data Assign Button Product Program Mode Modifying Product SettingsChange Product Names To Change Times and Temperatures Modifying Product SettingsAlarms 1 Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Filter Control Level 2 Programming Special Program ModeAudio Volume SP-4 Special Program ModeDegrees Fahrenheit or Celsius SP-1 Language SP-2Liquid or Solid Cooking Oil Used SP-6 Idle Mode Enabled SP-7Audio Tone SP-5 Mixed Filter Tracking Mode SP-8If Global is selected, press button GlobalClean-Out Temperature SP-12 Clean-Out Time SP-11Cooking Indicator SP-15 Polish Duration SP-9Engery Save Mode SP-18 2nd Volume SP-172nd Language SP-16 Fryer Type SP-19Bulk Oil Supply SP-22 Autolift Enabled SP-21Bulk Oil Disposal SP-23 Serial Number Log SP-24Dispose Requires Code ? SP-27 Usage Code Change SP-26Longer Fill Time SP-28 Let User Exit Fill SP-29Model EEG-141, 142, 143 Problem Cause Correction Troubleshooting Trouble Shooting GuideRemove the right side panel Display Cause Correction Error CodesClosed Error Codes Display Cause CorrectionPage Henny Penny Corporation Box Eaton,OH Toll free in USA