2-7. GAS LEAK TEST

2-8. GAS PRESSURE REGULATOR SETTING

2-9. ELECTRICAL REQUIREMENTS

Model EEG-141, 142, 143, 144

Prior to turning the gas supply on, be sure the gas valve knob on the gas control valve is in the off position.

Upon initial installation, and after moving the unit, the piping and fittings should be checked for gas leaks.Asimple checking method is to turn on the gas and brush all connections with a soap solution. If bubbles occur, it indicates escaping gas. In this event, the piping connection must be redone.

To avoid fire or explosion, never use a lighted match or open flame to test for gas leaks. Ignited gas could result in severe personal injury and/or property dam- age.

The gas pressure regulator on the gas control valve is factory set as follows:

Natural: 3.5 inches water column (0.87 kPa) (8.72 mbar).

Propane 10.0 inches water column (2.49 kPa) (24.9 mbar).

The gas pressure regulator has been set by Henny Penny and is not to be adjusted by the user.

120 V, 50/60 Hz, 1 PH, 12 A

230 V, 50 Hz, 1 PH, 7 A

The 120 volt gas fryer is factory equipped with a grounded (earthed) cord and plug for your protection against shock, and should be plugged into a three-prong grounded (earthed) recep- tacle. Do not cut or remove grounding (earthing) prong. Any 230 volt plug used on the 230 volt unit must conform to all local, state, and national codes.

To avoid electrical shock, this appliance must be equipped with an external circuit breaker which will disconnect all ungrounded (unearthed) conductors. The main power switch on this appliance does not disconnect all line conductors.

2-6

609

Image 18
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Features IntroductionProper Care Safety AssistanceSafety Page Installation UnpackingSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Electrical Requirements Motor Bearings Lightingand Shutdown of the BurnersDimensions Page Operation Operating Components Refer to explanations on the next pagesOperating Components DescriptionFunction Description Function JIB SET-UP Mode VAT Type Full or SplitFilling or Adding OIL Fill POT from BulkMorning START-UP Procedures Basic Operation Idle Mode OIL Guardian Auto Top-Off Selectinga Product Withadifferent Setpoint Replacing the JIBReservoir Removing/Cleaning ReservoirModel EEG-141 OIL Filling Oil ReservoirSmartfilter Express Filter Error Smartfilter ExpressDaily Filtering Check Filter Pan a new filter pad should be used onDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT Mode CLEAN-OUTCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Info Button Stats Actual Oil TemperatureRecovery Information for each Vat Filter Button StatsPreventive Maintenance Schedule ProcedureFrequencyClean Blower & Vents Page Information Mode Information Mode DetailsDetails Function Display EXTUE NEW OIL Reset usage data Product Program Mode Modifying Product Settings Change Product NamesAssign Button Alarms 1 Modifying Product SettingsTo Change Times and Temperatures Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Level 2 Programming Special Program Mode Filter ControlDegrees Fahrenheit or Celsius SP-1 Special Program ModeAudio Volume SP-4 Language SP-2Idle Mode Enabled SP-7 Audio Tone SP-5Liquid or Solid Cooking Oil Used SP-6 Filter Tracking Mode SP-8 MixedGlobal If Global is selected, press buttonCooking Indicator SP-15 Clean-Out Time SP-11Clean-Out Temperature SP-12 Polish Duration SP-92nd Language SP-16 2nd Volume SP-17Engery Save Mode SP-18 Fryer Type SP-19Bulk Oil Disposal SP-23 Autolift Enabled SP-21Bulk Oil Supply SP-22 Serial Number Log SP-24Longer Fill Time SP-28 Usage Code Change SP-26Dispose Requires Code ? SP-27 Let User Exit Fill SP-29Model EEG-141, 142, 143 Troubleshooting Trouble Shooting Guide Problem Cause CorrectionRemove the right side panel Error Codes Display Cause CorrectionError Codes Display Cause Correction ClosedPage Henny Penny Corporation Box Eaton,OH Toll free in USA