3-11. SMARTFILTER EXPRESS™ (Continued)

Model EEG-141, 142, 143, 144

6. If the oil has not pumped back to the proper levelXin the vat during the SmartFilter Express™ process, press button for NO and pump runs for another 30 seconds.

7.Display shows “IS POT FILLED?” “YES NO”. Make sure

vat is full and then press √ button and displayX shows and the control returns to normal operation. Press button and pump

runs for another 30 seconds. You can try to fill the vat 3 times.

Filter Error

8.After trying to fill the vat 3 times without success, the controls

then shows “CHANGE FILTER PAD?” “YES NO”. If changing the filter pad at this time, press √ and change filter pad following the procedures in the Changing the Filter Pad Section. Controls return to normal operation.

If filter pad is to be changed at a later time, press X button and “CHANGE FILTER PAD?” reminder shows 15 minutes later.

9.During the next SmartFilter Express™ with a new filter pad, if the vat is not filled after 3 tries, the display shows “FILTER SERVICE REQUIRED-SEE TROUBLESHOOTING GUIDE”.

If the “Service Required” message appears, then every 15 minutes the display shows “FILTER PROBLEMX FIXED? YES NO”. If the problem has not been fixed, press button. Once the problem has been resolved, press √ and controls return to normal operation.

To help ensure the vat fills completely, make sure filter pan is cleaned at least daily, filter pad is changed, make sure JIB is full and that “O” rings on the filter pan are in good condition.

609

3-12

Image 33
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Features IntroductionProper Care Assistance SafetySafety Page Unpacking InstallationSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Motor Bearings Lightingand Shutdown of the Burners Electrical RequirementsDimensions Page Refer to explanations on the next pages Operation Operating ComponentsOperating Components DescriptionFunction Description Function JIB VAT Type Full or Split SET-UP ModeFill POT from Bulk Filling or Adding OILMorning START-UP Procedures Basic Operation Idle Mode Selectinga Product Withadifferent Setpoint Replacing the JIB OIL Guardian Auto Top-OffModel EEG-141 OIL Removing/Cleaning ReservoirReservoir Filling Oil ReservoirSmartfilter Express Smartfilter Express Filter ErrorCheck Filter Pan a new filter pad should be used on Daily FilteringDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT CLEAN-OUT ModeCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Recovery Information for each Vat Actual Oil TemperatureInfo Button Stats Filter Button StatsProcedureFrequency Preventive Maintenance ScheduleClean Blower & Vents Page Information Mode Details Information ModeFunction Display EX DetailsTUE NEW OIL Reset usage data Product Program Mode Modifying Product Settings Change Product NamesAssign Button To Change Times and Temperatures Modifying Product SettingsAlarms 1 Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Filter Control Level 2 Programming Special Program ModeAudio Volume SP-4 Special Program ModeDegrees Fahrenheit or Celsius SP-1 Language SP-2Idle Mode Enabled SP-7 Audio Tone SP-5Liquid or Solid Cooking Oil Used SP-6 Mixed Filter Tracking Mode SP-8If Global is selected, press button GlobalClean-Out Temperature SP-12 Clean-Out Time SP-11Cooking Indicator SP-15 Polish Duration SP-9Engery Save Mode SP-18 2nd Volume SP-172nd Language SP-16 Fryer Type SP-19Bulk Oil Supply SP-22 Autolift Enabled SP-21Bulk Oil Disposal SP-23 Serial Number Log SP-24Dispose Requires Code ? SP-27 Usage Code Change SP-26Longer Fill Time SP-28 Let User Exit Fill SP-29Model EEG-141, 142, 143 Problem Cause Correction Troubleshooting Trouble Shooting GuideRemove the right side panel Display Cause Correction Error CodesClosed Error Codes Display Cause CorrectionPage Henny Penny Corporation Box Eaton,OH Toll free in USA