Henny Penny EEG-141, EEG-142, EEG-144 Level 2 Programming Special Program Mode, Filter Control

Page 57

Model EEG-141, 142, 143, 144

SECTION 6. LEVEL 2 PROGRAMMING

6-1. SPECIAL PROGRAM MODE

Used to access the following:

 

 

• Special Program Mode

• Tech Mode

• Clock Set

• Stats

• Data Communication

• Filter Control

• Heat Control

 

 

The Special Program Mode is used to set more detailed

programming, such as:

 

 

SP-1

• Degrees Fahrenheit or Celsius

 

SP-2

• Language: English, Russian, Swedish (SVENSKT),

 

 

 

German (DEUTSCHE), Portuguese, Spanish (ESPANOL)

SP-3

 

and French (FRANCAIS)

 

 

System Initialization (Factory Presets)

SP-4

• Audio Volume

 

 

SP-5

Audio Tone

 

 

SP-6

Melt Cycle Select - 1.LIQUID; 2.SOLID

SP-7

• Idle Mode Enabled - YES or NO

SP-7A

Use “0” for IDLE

 

 

SP-7B

• Auto Idle Minutes

 

 

SP-7C

Idle Set-point Temperature

 

 

SP-8

Filter Tracking Mode - 1.MIXED or 2.GLOBAL

SP-8A

Suggest Filter At... - 75% to 100% (MIXED)

SP-8B

Filter Lockout Enabled? - YES or NO (MIXED)

SP-8A

Left Vat Filter Cycles - 0 to 99

(GLOBAL)

SP-8B

Right Vat Filter Cycles - 0 to 99

(GLOBAL)

SP-8C

Filter Lockout Enabled? - YES or NO (GLOBAL)

SP-9

Polish Duration - X:XX M:SS

 

 

SP-10

Change Pad Reminder Time - XX HRS

SP-11

Clean-Out Time - XX MIN

 

 

SP-12

Clean-Out Temperature - XXX oF or C

SP-13

• Cooking User IO - After Cook Cycle, display shows

SP-14

 

previous menu item or “----”

 

 

Number of Baskets - 2-BASKETS or 4 BASKETS

SP-15

Show Cooking Indicator - YES or NO

SP-16

 

 

 

 

2nd Language: English, Russian, Swedish (SVENSKT), German (DEUTSCHE), Portuguese, Spanish (ESPANOL)

SP-17

and French (FRANCAIS)

2nd AudioVolume

SP-18

Energy Save Enabled? - YES or NO

SP-19

Fryer Type - GAS or ELECTRIC

SP-20

Vat Type - SPLIT or FULL

SP-21

Autolift Enabled? - NO LIFT or YES LIFT

SP-22

• Bulk Oil Supply? - YES or NO

SP-23

Direct Oil Dispose? - YES or NO

SP-24

Serial No. of Fryer

SP-25

Change Mgr. Code- 1 = YES

SP-26

Change Usage Code - 1 = YES

SP-27

Dispose Requires Code ? - YES or NO

SP-28

• Longer Fill Time Enabled - YES or NO

SP-29

Let User Exit Fill? - YES or NO

1009

6-1

Image 57
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Features IntroductionProper Care Assistance SafetySafety Page Unpacking InstallationSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Motor Bearings Lightingand Shutdown of the Burners Electrical RequirementsDimensions Page Refer to explanations on the next pages Operation Operating ComponentsOperating Components DescriptionFunction Description Function JIB VAT Type Full or Split SET-UP ModeFill POT from Bulk Filling or Adding OILMorning START-UP Procedures Basic Operation Idle Mode Selectinga Product Withadifferent Setpoint Replacing the JIB OIL Guardian Auto Top-OffModel EEG-141 OIL Removing/Cleaning ReservoirReservoir Filling Oil ReservoirSmartfilter Express Smartfilter Express Filter ErrorCheck Filter Pan a new filter pad should be used on Daily FilteringDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT CLEAN-OUT ModeCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Recovery Information for each Vat Actual Oil TemperatureInfo Button Stats Filter Button StatsProcedureFrequency Preventive Maintenance ScheduleClean Blower & Vents Page Information Mode Details Information ModeFunction Display EX DetailsTUE NEW OIL Reset usage data Product Program Mode Modifying Product Settings Change Product NamesAssign Button To Change Times and Temperatures Modifying Product SettingsAlarms 1 Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Filter Control Level 2 Programming Special Program ModeAudio Volume SP-4 Special Program ModeDegrees Fahrenheit or Celsius SP-1 Language SP-2Idle Mode Enabled SP-7 Audio Tone SP-5Liquid or Solid Cooking Oil Used SP-6 Mixed Filter Tracking Mode SP-8If Global is selected, press button GlobalClean-Out Temperature SP-12 Clean-Out Time SP-11Cooking Indicator SP-15 Polish Duration SP-9Engery Save Mode SP-18 2nd Volume SP-172nd Language SP-16 Fryer Type SP-19Bulk Oil Supply SP-22 Autolift Enabled SP-21Bulk Oil Disposal SP-23 Serial Number Log SP-24Dispose Requires Code ? SP-27 Usage Code Change SP-26Longer Fill Time SP-28 Let User Exit Fill SP-29Model EEG-141, 142, 143 Problem Cause Correction Troubleshooting Trouble Shooting GuideRemove the right side panel Display Cause Correction Error CodesClosed Error Codes Display Cause CorrectionPage Henny Penny Corporation Box Eaton,OH Toll free in USA