3-22. CLEAN BLOWER & VENTS

Figure 1

Figure 2

Figure 3

Figure 4

1109

Model EEG-141, 142, 143, 144

To ensure proper burner operation, clean the blowers and blower vents twice a year.

1.Press the main power switch to the OFF posistion.

2.Unplug power cord and turn the gas shut-off handle clockwise to turn off the gas, and then disconnect the gas line.

3.Disconnect cable restraint and then carefully roll the fryer from the hood far enough to get behind the fryer.

To avoid burns, use care when moving the fryer to prevent hot cooking oil from splashing.

4.Using a cloth or paper towel, clean the blower intake slots to ensure sufficient air flow to the blowers. Figure 1.

5.Using a Phillip’s-Head screwdriver, remove lower, rear panel. Figure 2.

6.Using a cloth or paper towel, clean each blower opening. Figure 3.

7.Clean the vent slots on the inside of rear panel, and then replace panel. Figure 4.

8.Reattach the gas line and turn the shut-off handle counter- clockwise to turn on the gas and reconnect the cable restraint to the fryer.

9.Reattach the plug to electrical receptacle and roll fryer back into place.

3-26

Image 47
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Proper Care FeaturesIntroduction Assistance SafetySafety Page Unpacking InstallationSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Motor Bearings Lightingand Shutdown of the Burners Electrical RequirementsDimensions Page Refer to explanations on the next pages Operation Operating ComponentsFunction Operating ComponentsDescription Description Function JIB VAT Type Full or Split SET-UP ModeFill POT from Bulk Filling or Adding OILMorning START-UP Procedures Basic Operation Idle Mode Selectinga Product Withadifferent Setpoint Replacing the JIB OIL Guardian Auto Top-OffFilling Oil Reservoir Removing/Cleaning ReservoirModel EEG-141 OIL ReservoirSmartfilter Express Smartfilter Express Filter ErrorCheck Filter Pan a new filter pad should be used on Daily FilteringDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT CLEAN-OUT ModeCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Filter Button Stats Actual Oil TemperatureRecovery Information for each Vat Info Button StatsProcedureFrequency Preventive Maintenance ScheduleClean Blower & Vents Page Information Mode Details Information ModeFunction Display EX DetailsTUE NEW OIL Reset usage data Assign Button Product Program Mode Modifying Product SettingsChange Product Names Quality Timer hold time Modifying Product SettingsTo Change Times and Temperatures Alarms 1MixFilterdAfterFil TrackingX Number of Loads Filter Control Level 2 Programming Special Program ModeLanguage SP-2 Special Program ModeAudio Volume SP-4 Degrees Fahrenheit or Celsius SP-1Liquid or Solid Cooking Oil Used SP-6 Idle Mode Enabled SP-7Audio Tone SP-5 Mixed Filter Tracking Mode SP-8If Global is selected, press button GlobalPolish Duration SP-9 Clean-Out Time SP-11Clean-Out Temperature SP-12 Cooking Indicator SP-15Fryer Type SP-19 2nd Volume SP-17Engery Save Mode SP-18 2nd Language SP-16Serial Number Log SP-24 Autolift Enabled SP-21Bulk Oil Supply SP-22 Bulk Oil Disposal SP-23Let User Exit Fill SP-29 Usage Code Change SP-26Dispose Requires Code ? SP-27 Longer Fill Time SP-28Model EEG-141, 142, 143 Problem Cause Correction Troubleshooting Trouble Shooting GuideRemove the right side panel Display Cause Correction Error CodesClosed Error Codes Display Cause CorrectionPage Henny Penny Corporation Box Eaton,OH Toll free in USA