Henny Penny EEG-142 Autolift Enabled SP-21, Bulk Oil Supply SP-22, Bulk Oil Disposal SP-23

Page 64

6-1. SPECIAL PROGRAM MODE (Continued)

6-8

Model EEG-141, 142, 143, 144

Autolift Enabled (SP-21)

Press button and “SP-21 AUTOLIFT ENABLED?” flashes in the left display. Press the or buttons to choose “YES LIFT” or “NO LIFT”.

If fryer is fitted with the auto-lift option, SP-21 must be set to “YES LIFT”, otherwise, set SP-21 to “NO LIFT”.

Bulk Oil Supply (SP-22)

Press button and “SP-22 BULK OIL SUPPLY?” flashes in the left display. Press the or buttons to choose “YES SUPL” or “NO SUPL”.

Set to YES if the oil is pumped into the vats from an outside oil reservoir. Otherwise, set SP-22 to NO.

Bulk Oil Disposal (SP-23)

Press button and “SP-23 BULK OIL DISPOSE?”

flashes in the left display. Press the or buttons to choose “YES DISP” or “NO DISP”.

Set to “YES DISP” if the oil is pumped from the vats to an outside oil reservoir when disarding the oil. Otherwise, set SP-23 to “NO DISP”.

Serial Number Log (SP-24)

Press button and “SP-24 S/N √EDIT” flashes in the displays, along with the serial number of the unit. THIS SERIAL NUMBER SHOULD MATCH THE SERIAL NUMBER ON THE DATA PLATE, ON THE DOORS. IF NOT, IT CAN BE RECORDED.

Program Code Change (SP-25)

This allows the operator to change the program code (factory set at 1, 2, 3) used to access Product Programming and Level 2 Program Mode.

Press button and “SP-25 CHANGE MGR CODE? 1=YES” flash in the display. Press and “ENTER NEW CODE, P=DONE, I=QUIT show scrolls through the display. Press the product buttons for new code.

If satisfied with code, press and “REPEAT NEW CODE, P=DONE, I=QUIT, shows in display. Press same code buttons.

609

Image 64
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Introduction FeaturesProper Care Safety AssistanceSafety Page Installation UnpackingSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Electrical Requirements Motor Bearings Lightingand Shutdown of the BurnersDimensions Page Operation Operating Components Refer to explanations on the next pagesDescription Operating ComponentsFunction Description Function JIB SET-UP Mode VAT Type Full or SplitFilling or Adding OIL Fill POT from BulkMorning START-UP Procedures Basic Operation Idle Mode OIL Guardian Auto Top-Off Selectinga Product Withadifferent Setpoint Replacing the JIBRemoving/Cleaning Reservoir Model EEG-141 OILReservoir Filling Oil ReservoirSmartfilter Express Filter Error Smartfilter ExpressDaily Filtering Check Filter Pan a new filter pad should be used onDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT Mode CLEAN-OUTCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Actual Oil Temperature Recovery Information for each VatInfo Button Stats Filter Button StatsPreventive Maintenance Schedule ProcedureFrequencyClean Blower & Vents Page Information Mode Information Mode DetailsDetails Function Display EXTUE NEW OIL Reset usage data Change Product Names Product Program Mode Modifying Product SettingsAssign Button Modifying Product Settings To Change Times and TemperaturesAlarms 1 Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Level 2 Programming Special Program Mode Filter ControlSpecial Program Mode Audio Volume SP-4Degrees Fahrenheit or Celsius SP-1 Language SP-2Audio Tone SP-5 Idle Mode Enabled SP-7Liquid or Solid Cooking Oil Used SP-6 Filter Tracking Mode SP-8 MixedGlobal If Global is selected, press buttonClean-Out Time SP-11 Clean-Out Temperature SP-12Cooking Indicator SP-15 Polish Duration SP-92nd Volume SP-17 Engery Save Mode SP-182nd Language SP-16 Fryer Type SP-19Autolift Enabled SP-21 Bulk Oil Supply SP-22Bulk Oil Disposal SP-23 Serial Number Log SP-24Usage Code Change SP-26 Dispose Requires Code ? SP-27Longer Fill Time SP-28 Let User Exit Fill SP-29Model EEG-141, 142, 143 Troubleshooting Trouble Shooting Guide Problem Cause CorrectionRemove the right side panel Error Codes Display Cause CorrectionError Codes Display Cause Correction ClosedPage Henny Penny Corporation Box Eaton,OH Toll free in USA