6-1. SPECIAL PROGRAM MODE (Continued)
| No. Cook | Cycle |
Product | Cycles | Count |
Fish | 2 | 1/2 |
French Fries | 8 | 1/8 |
Chicken | 4 | 1/4 |
Model EEG-141, 142, 143, 144
Filter Tracking Mode (SP-8)
Filter Tracking signals the operator when the oil needs filtering by counting the number Cook Cycles between filters
Press button and
GLOBAL means all the products have the same number of cook cycles between filters.
MIXED means each product may be set with different number of cook cycles between filters. The controls adds the
cycle counts (see example at left) and when the counts equal 1 or greater, filtering is suggested. Ex: 1 load of fish, 2 loads of french fries, a load of chicken equals 1. 1/2 + 1/8+1/8+1/4=1.
MIXED
If MIXED is selected, press button and
The lower the value, the sooner the control recommends to filter. Ex: If set to 75%, the control suggest filtering after 3/4 of the programmed cook cycles is met, whereas at 100%, all the cook cycles must be completed before the control suggest filtering.
Press and
If set toYES, when the controls suggest filtering, “FILTER LOCKOUT”/”YOU *MUST* FILTER NOW”, shows in the display, and it refuses further cook cycles until the vat is filtered.
Press and
right display. Press the and buttons to change this value. The lower the value, the sooner the “lockout” occurs.
Ex: If set at 100%, “lockout” occurs when the cycle counts reaches 1 or greater. Set at 200%, twice as many cycles are counted before “lockout” occurs. See example above.
909 |