Henny Penny EEG-142, EEG-141, EEG-144, EEG-143 warranty Filter Tracking Mode SP-8, Mixed

Page 60

6-1. SPECIAL PROGRAM MODE (Continued)

 

No. Cook

Cycle

Product

Cycles

Count

Fish

2

1/2

French Fries

8

1/8

Chicken

4

1/4

Model EEG-141, 142, 143, 144

Filter Tracking Mode (SP-8)

Filter Tracking signals the operator when the oil needs filtering by counting the number Cook Cycles between filters

Press button and “SP-8” and “FILTER TRACKING MODE” show in the display. Use the and buttons to choose either “1.MIXED” filter tracking or “2.GLOBAL”.

GLOBAL means all the products have the same number of cook cycles between filters.

MIXED means each product may be set with different number of cook cycles between filters. The controls adds the

cycle counts (see example at left) and when the counts equal 1 or greater, filtering is suggested. Ex: 1 load of fish, 2 loads of french fries, a load of chicken equals 1. 1/2 + 1/8+1/8+1/4=1.

MIXED

If MIXED is selected, press button and “SP-8A” and “SUGGEST FILTERAT …” shows in the left display, and a value between 75% and 100% shows on the right display. Press the and buttons to change this value.

The lower the value, the sooner the control recommends to filter. Ex: If set to 75%, the control suggest filtering after 3/4 of the programmed cook cycles is met, whereas at 100%, all the cook cycles must be completed before the control suggest filtering.

Press and “SP-8B” and “LOCKOUT ENABLED?” shows in the left display. Press the and buttons to choose YES or NO.

If set toYES, when the controls suggest filtering, “FILTER LOCKOUT”/”YOU *MUST* FILTER NOW”, shows in the display, and it refuses further cook cycles until the vat is filtered.

Press and “SP-8C” and “LOCKOUT AT...” shows in the left display and a value between 100% and 250% shows on the

right display. Press the and buttons to change this value. The lower the value, the sooner the “lockout” occurs.

Ex: If set at 100%, “lockout” occurs when the cycle counts reaches 1 or greater. Set at 200%, twice as many cycles are counted before “lockout” occurs. See example above.

6-4

909

Image 60
Contents OPERATOR’S Manual Page FM05-057-C Revised Technical Data for CE Marked Products Limited Warranty for Henny Penny Equipment Table of Contents Section Table of Contents Page Features IntroductionProper Care Safety AssistanceSafety Page Installation UnpackingSelecting the Fryer Location Leveling the Fryer GAS Supply GAS Supply GAS Supply Model EEG-141, 142, 143 Electrical Requirements Motor Bearings Lightingand Shutdown of the BurnersDimensions Page Operation Operating Components Refer to explanations on the next pagesOperating Components DescriptionFunction Description Function JIB SET-UP Mode VAT Type Full or SplitFilling or Adding OIL Fill POT from BulkMorning START-UP Procedures Basic Operation Idle Mode OIL Guardian Auto Top-Off Selectinga Product Withadifferent Setpoint Replacing the JIBRemoving/Cleaning Reservoir Model EEG-141 OILReservoir Filling Oil ReservoirSmartfilter Express Filter Error Smartfilter ExpressDaily Filtering Check Filter Pan a new filter pad should be used onDaily Filtering Discarding OIL from VAT Using Optional OIL Discard Shuttle Express FILTER? Changing the Filter PAD Changing the Filter PAD Removing and Cleaning Basket Rest CLEAN-OUT Mode CLEAN-OUTCLEAN-OUT Mode Rinse Complete YES no CHECK/REPLACE Filter Drain PAN O-RINGS Actual Oil Temperature Recovery Information for each VatInfo Button Stats Filter Button StatsPreventive Maintenance Schedule ProcedureFrequencyClean Blower & Vents Page Information Mode Information Mode DetailsDetails Function Display EXTUE NEW OIL Reset usage data Product Program Mode Modifying Product Settings Change Product NamesAssign Button Modifying Product Settings To Change Times and TemperaturesAlarms 1 Quality Timer hold timeMixFilterdAfterFil TrackingX Number of Loads Level 2 Programming Special Program Mode Filter ControlSpecial Program Mode Audio Volume SP-4Degrees Fahrenheit or Celsius SP-1 Language SP-2Idle Mode Enabled SP-7 Audio Tone SP-5Liquid or Solid Cooking Oil Used SP-6 Filter Tracking Mode SP-8 MixedGlobal If Global is selected, press buttonClean-Out Time SP-11 Clean-Out Temperature SP-12Cooking Indicator SP-15 Polish Duration SP-92nd Volume SP-17 Engery Save Mode SP-182nd Language SP-16 Fryer Type SP-19Autolift Enabled SP-21 Bulk Oil Supply SP-22Bulk Oil Disposal SP-23 Serial Number Log SP-24Usage Code Change SP-26 Dispose Requires Code ? SP-27Longer Fill Time SP-28 Let User Exit Fill SP-29Model EEG-141, 142, 143 Troubleshooting Trouble Shooting Guide Problem Cause CorrectionRemove the right side panel Error Codes Display Cause CorrectionError Codes Display Cause Correction ClosedPage Henny Penny Corporation Box Eaton,OH Toll free in USA