Henny Penny OFE- 291 manual LID Operation

Page 2

 

 

Model OFE- 291

3-1. OPERATING COMPONENTS

 

 

(Continued)

 

 

High Limit

This high temperature control senses the temperature of the

 

shortening; if the temperature of the shortening exceeds

 

450°F (230°C), this control will open and shut off the heat

 

to the frypot; when the temperature of the shortening drops

 

to a safe operation limit, the control must be manually reset by

 

pressing the red reset button, located under the control panel, in the

 

right, front of the fryer

Figure 3-1

 

 

Filter Drain Pan

The removable pan that houses the filter and catches the shortening

 

when it is drained from the frypot; also used to remove anddiscard

 

old shortening

 

 

When hot shortening is in this pan, use extreme care to

 

 

avoid burns.

Filter Union

Connects the filter to the filter pump, and allows easy removal of the

 

filter and drain pan

Fuses

A protective device which breaks the circuit when the current

 

exceeds the rated value

3-2. LID OPERATION

To close lid:

 

1.

Lower the lid until latch comes into contact with the pot.

 

To open lid:

 

1.

Unlatch the front lid latch.

 

2.

Lift up on handle to raise lid.

3-2

703

Image 2
Contents Operation Operating Components LID Operation Description Function SwitchesIndicators Switches and Indicators Description Function Model OFE 403 Clock SET Clock SET Filling or Adding Shortening Product Racking Recommendations Be Certain the Shortening is Never Above the Upper Frypot LevelindicatorBasic Operation LINE. Failure to Follow These InstrucAllow fryer to heat until Illuminates Unlatch and raise the lid cautiously Which could Result in Serious Burns Care ShorteningShortening Overflowingthe Frypot Personal INJURY, FIRE, AND/OR PropertyFiltering Instructions Filtering Instructions Only Connectand Disconnect the Filter Rinse Hose When the Main Power SwitchFiltering Instructions Is in the OFF POSITION. ALSO, USE a DRYEnvelope Filter Pump Motor PROTECTOR-MANUAL Reset Cleaningthe Frypot If hot shortening is present in the frypot, it must be Drained by slowly pulling the drain handle out towards youCleaning the Frypot Does not boil over causing damage to controlsMaintenance Procedure FrequencyCleaning Nylatrons Monthly PreventiveProgramming Change Product NamesProgramming Go to Idle after Done? Filter Cycle Mode OptionalProgramming Global Erase a Prod Preset a Prod Erase ALL Special Program ModeSystem Initialization SP-3 Language SP-2 ModeAudio Volume SP-4 Audio Tone SP-5Idle Mode SP-7 Type of shortening to be melted Liquid or Solid SP-6Mixed Press SP-8C shows in the display, if YES Special Program Schedule To filter the shortening. Press To changeClean-Out Temperature Sp-11 Product Buttons Sp-9 ModeClean-Out Temperature Sp-10 Mode Program Code Change SP-15 Usage Code Change SP-16If satisfied with code, press Mode Shows in display If not satisfied with code, pressData LOGGING, Heat CONTROL, Tech MODE, and Stat Mode Code ChangePress to continue to Last Load Information Mode Last Load Function DisplayexInformation Mode Function Display EXOutp H* P Analog 1 OIL TMPCPU TMP