Henny Penny OFE- 291 manual Envelope

Page 17

 

 

Model OFE- 291

3-10. CHANGING THE FILTER

 

 

ENVELOPE (Continued)

4.

Lift the filter screen assembly from the drain pan.

 

5.

Wipe the shortening and crumbs from the filter drain pan.

 

 

Clean the filter drain pan with soap and water. Thoroughly

 

 

rinse with hot water.

 

6.

Unthread the standpipe from the filter screen assembly.

 

7.

Remove the crumb catcher and clean thoroughly with

 

 

hot water.

 

8.

Remove the filter clips and discard the filter envelope.

 

9.

Clean the top and bottom filter screen with soap and

 

 

water. Rinse thoroughly with hot water.

 

 

Be sure that the filter screens, crumb catcher, filter clips,

 

 

and the standpipe are thoroughly dry before assembly of

 

 

filter envelope as water will dissolve the filter paper.

 

10.

Assemble the top filter screen to the bottom filter screen.

 

11.

Slide the screens into a clean filter envelope.

 

12.

Fold the corners in and then double fold the open end.

 

13.

Clamp the envelope in place with the two filter retaining clips.

 

14.

Replace the crumb catcher screen on top of the filter

 

 

paper. Screw on the standpipe assembly.

 

15.

Place complete filter screen assembly back into filter

 

 

drain pan and slide pan back into place beneath the fryer.

 

16.

Connect the filter union by hand. Do not use a wrench to

 

 

tighten.

 

17.

Slide the condensation drain pan back into place. The

 

 

fryer is now ready to operate.

703

3-17

Image 17
Contents Operation Operating Components LID Operation Description Function SwitchesIndicators Switches and Indicators Description Function Model OFE 403 Clock SET Clock SET Filling or Adding Shortening Product Racking Recommendations Basic Operation Above the Upper Frypot LevelindicatorBe Certain the Shortening is Never LINE. Failure to Follow These InstrucAllow fryer to heat until Illuminates Unlatch and raise the lid cautiously Shortening Overflowingthe Frypot Care ShorteningWhich could Result in Serious Burns Personal INJURY, FIRE, AND/OR PropertyFiltering Instructions Filtering Instructions Filtering Instructions Rinse Hose When the Main Power SwitchOnly Connectand Disconnect the Filter Is in the OFF POSITION. ALSO, USE a DRYEnvelope Filter Pump Motor PROTECTOR-MANUAL Reset Cleaningthe Frypot Drained by slowly pulling the drain handle out towards you If hot shortening is present in the frypot, it must beDoes not boil over causing damage to controls Cleaning the FrypotCleaning Nylatrons Monthly Procedure FrequencyMaintenance PreventiveChange Product Names ProgrammingProgramming Go to Idle after Done? Filter Cycle Mode OptionalProgramming Global Erase a Prod Preset a Prod Erase ALL Mode Special ProgramAudio Volume SP-4 Language SP-2 ModeSystem Initialization SP-3 Audio Tone SP-5Type of shortening to be melted Liquid or Solid SP-6 Idle Mode SP-7Mixed Press SP-8C shows in the display, if YES To filter the shortening. Press To change Special Program ScheduleClean-Out Temperature Sp-11 Product Buttons Sp-9 ModeClean-Out Temperature Sp-10 Usage Code Change SP-16 Mode Program Code Change SP-15Data LOGGING, Heat CONTROL, Tech MODE, and Stat Mode Mode Shows in display If not satisfied with code, pressIf satisfied with code, press Code ChangePress to continue to Last Load Function Displayex Information Mode Last LoadFunction Display EX Information ModeOutp H* P Analog 1 OIL TMPCPU TMP