3-15. PROGRAMMING (Continued)

Model OFE- 291

11.Press and release and “LOAD COMP” shows in

the display along with the load compensation value. This automatically adjusts the time to account for the size and temperature of the cooking load. Press and release

to change this value to a max. of 20 and a min. of 0, or “OFF”. Preset at factory at 5.

12.Press and release and “LCOMP REF” shows in

the display (if load compensation is set to “OFF”, then

“_ _ _” shows in display) along with the load compensation average temperature. This is your average cooking temperature for the products you cook. The timer speeds up at temperature above this setting and slows down at temperatures below this setting. Press and release

to change this value.

Or, to use the cooking setpoint temperature as the load compensation reference point, press until “STEP-X” and “TEMP” flashes in the display. Now for example, if the cooking temperature is 350°, the timer speeds up when the shortening temperature is above 350, and slows down when the temperature is below 350.

13.Go to Idle after Done?

Press and release and “GO TO IDLE, AFTER

DONE” shows in the display, along with “YES” or

“NO”. Press to toggle between YES and NO.

14.Filter Cycle Mode (Optional)

For “FILTER AFTER” to appear in the Product Program Mode, the Filter Tracking must be enabled in the Special Program Mode. You have the option to program “mixed” (each product has its own filter count) or “global” (all products have the same count).

Press .

403

3-24

Image 24
Contents Operation Operating Components LID Operation Switches IndicatorsDescription Function Switches and Indicators Description Function Model OFE 403 Clock SET Clock SET Filling or Adding Shortening Product Racking Recommendations Above the Upper Frypot Levelindicator Basic OperationBe Certain the Shortening is Never LINE. Failure to Follow These InstrucAllow fryer to heat until Illuminates Unlatch and raise the lid cautiously Care Shortening Shortening Overflowingthe FrypotWhich could Result in Serious Burns Personal INJURY, FIRE, AND/OR PropertyFiltering Instructions Filtering Instructions Rinse Hose When the Main Power Switch Filtering InstructionsOnly Connectand Disconnect the Filter Is in the OFF POSITION. ALSO, USE a DRYEnvelope Filter Pump Motor PROTECTOR-MANUAL Reset Cleaningthe Frypot If hot shortening is present in the frypot, it must be Drained by slowly pulling the drain handle out towards youCleaning the Frypot Does not boil over causing damage to controlsProcedure Frequency Cleaning Nylatrons MonthlyMaintenance PreventiveProgramming Change Product NamesProgramming Filter Cycle Mode Optional ProgrammingGo to Idle after Done? Global Erase a Prod Preset a Prod Erase ALL Special Program ModeLanguage SP-2 Mode Audio Volume SP-4System Initialization SP-3 Audio Tone SP-5Idle Mode SP-7 Type of shortening to be melted Liquid or Solid SP-6Mixed Press SP-8C shows in the display, if YES Special Program Schedule To filter the shortening. Press To changeProduct Buttons Sp-9 Mode Clean-Out Temperature Sp-10Clean-Out Temperature Sp-11 Mode Program Code Change SP-15 Usage Code Change SP-16Mode Shows in display If not satisfied with code, press Data LOGGING, Heat CONTROL, Tech MODE, and Stat ModeIf satisfied with code, press Code ChangePress to continue to Last Load Information Mode Last Load Function DisplayexInformation Mode Function Display EXOutp H* P OIL TMP CPU TMPAnalog 1