Model OFE- 291

3-15. PROGRAMMING

“2,Mixed”

 

(Continued)

a. “FILTER AFTER” shows in the display, along with

 

the preset number of Cook Cycles.

 

b. Press and release

until the desired number of

 

Cook Cycles between filters shows in the display. For

 

example, if 4 is set for a product, each time that product

 

is selected, it counts 1/4, or 25%. Then each time a

 

product is cooked, the percentages add up until 100%,

 

or more is reached. Then display shows “FILTER

 

SUGGESTED”.

 

 

“3,GLOBAL”

 

 

a. “FILTER INCL” shows in the display, along with “NO”

 

or “YES”

 

 

b. Press and release

to “YES” if that product is

 

to be included in the filter count, or “NO” if it is not.

Copy/Erase Pre-set Products

Products and their setpoints can be copied from one menu location on the controller to another location, preset the controls to factory settings, or erase products and all their values.

1.Press and hold for one second until “PROG” shows in the display, followed by “ENTER CODE”.

2.Enter code 1, 2, 3. “SELECT PRODUCT…PRESS PROG” scrolls across the display, followed by

“DOWN” FOR OPTIONS”

3. Press

and “**OPTION**”, followed by

“*1. COPY A PROD” shows in display. Press

again, each time, to view the following options:

*1.

COPY A PROD

*2.

ERASE A PROD

*3.

PRESET A PROD

*4.

ERASE ALL

*5.

PRESET ALL

4.To select one of the above options, press while the desired option shows in display. Selecting PRESET A PROD, or PRESET ALL PROD sets factory setpoints in those menu items.

Selecting PRESET A PROD, or PRESET ALL PROD sets factory setpoints in those menu items.

Press at any time to exit the options menu, or wait 30 seconds and controller automatically exits.

3-25

403

Image 25
Contents Operation Operating Components LID Operation Indicators SwitchesDescription Function Switches and Indicators Description Function Model OFE 403 Clock SET Clock SET Filling or Adding Shortening Product Racking Recommendations Basic Operation Above the Upper Frypot LevelindicatorBe Certain the Shortening is Never LINE. Failure to Follow These InstrucAllow fryer to heat until Illuminates Unlatch and raise the lid cautiously Shortening Overflowingthe Frypot Care ShorteningWhich could Result in Serious Burns Personal INJURY, FIRE, AND/OR PropertyFiltering Instructions Filtering Instructions Filtering Instructions Rinse Hose When the Main Power SwitchOnly Connectand Disconnect the Filter Is in the OFF POSITION. ALSO, USE a DRYEnvelope Filter Pump Motor PROTECTOR-MANUAL Reset Cleaningthe Frypot Drained by slowly pulling the drain handle out towards you If hot shortening is present in the frypot, it must beDoes not boil over causing damage to controls Cleaning the FrypotCleaning Nylatrons Monthly Procedure FrequencyMaintenance PreventiveChange Product Names ProgrammingProgramming Programming Filter Cycle Mode OptionalGo to Idle after Done? Global Erase a Prod Preset a Prod Erase ALL Mode Special ProgramAudio Volume SP-4 Language SP-2 ModeSystem Initialization SP-3 Audio Tone SP-5Type of shortening to be melted Liquid or Solid SP-6 Idle Mode SP-7Mixed Press SP-8C shows in the display, if YES To filter the shortening. Press To change Special Program ScheduleClean-Out Temperature Sp-10 Product Buttons Sp-9 ModeClean-Out Temperature Sp-11 Usage Code Change SP-16 Mode Program Code Change SP-15Data LOGGING, Heat CONTROL, Tech MODE, and Stat Mode Mode Shows in display If not satisfied with code, pressIf satisfied with code, press Code ChangePress to continue to Last Load Function Displayex Information Mode Last LoadFunction Display EX Information ModeOutp H* P CPU TMP OIL TMPAnalog 1