Model OFE- 291

3-16. SPECIAL PROGRAM

SCHEDULE

 

MODE (Continued)

m. If “4,SCHED” is selected, “SP-8A” shows in the display, and

 

followed by “SCHEDULE”. Press the

and up

to 4 different times of day can be programmed, by pressing

.

.

EX:

SP-8A “SCHEDULE” F1: 10.00A

SP-8B “SCHEDULE” F2: 2.00P

SP-8C “SCHEDULE” F3: 8.00P

SP-8D “SCHEDULE” F4: - - - -

Unneeded times should be left at “- - - -”, otherwise, “Filter Suggested” shows in the display, prompting the operator to start filtering.

Cooking is still permitted during the “suggested” phase. However, if lockout is enabled, and the fryer still has

not been filtered after one hour, then the controller activates lockout mode and prompts “FILTER LOCKOUT – YOU *MUST* FILTER NOW”.

n.Press and “SP-8E” “SKIP IF

LESS THAN...” shows in the display, followed by the number of loads between filters, ex: “LOAD 4”. In this example, if the suggested filter time occurs, before

4 loads have been cooked, then the filter operation is skipped. If more than 4 loads have been cooked, then “Filter Suggested” shows in the display. The numbers

of loads can be set by pressing

.

o. Press

and “SP-8F” shows in the display, followed by

“LOCKOUT ENABLED?” Press

to choose

“YES” or “NO”.

 

p. Press

and “SP-8G” shows in the display followed by

SP-8G “LOCKOUT - HEAT OIL...” and a shortening temperature, when reached, allows the operator to filter. Example, “LOCKOUT - HEAT OIL... 300F” means the display shows “FILTER LOCKOUT” “WAIT”, until 300F is reached, then display shows “FILTER LOCKOUT”/”YOU *MUST* FILTER NOW”, and repeated high-low tones are activated. This prompts the user that it is now time

to filter the shortening. Press

to change.

1005

3-32

Image 32
Contents Operation Operating Components LID Operation Description Function SwitchesIndicators Switches and Indicators Description Function Model OFE 403 Clock SET Clock SET Filling or Adding Shortening Product Racking Recommendations Above the Upper Frypot Levelindicator Basic OperationBe Certain the Shortening is Never LINE. Failure to Follow These InstrucAllow fryer to heat until Illuminates Unlatch and raise the lid cautiously Care Shortening Shortening Overflowingthe FrypotWhich could Result in Serious Burns Personal INJURY, FIRE, AND/OR PropertyFiltering Instructions Filtering Instructions Rinse Hose When the Main Power Switch Filtering InstructionsOnly Connectand Disconnect the Filter Is in the OFF POSITION. ALSO, USE a DRYEnvelope Filter Pump Motor PROTECTOR-MANUAL Reset Cleaningthe Frypot If hot shortening is present in the frypot, it must be Drained by slowly pulling the drain handle out towards youCleaning the Frypot Does not boil over causing damage to controlsProcedure Frequency Cleaning Nylatrons MonthlyMaintenance PreventiveProgramming Change Product NamesProgramming Go to Idle after Done? Filter Cycle Mode OptionalProgramming Global Erase a Prod Preset a Prod Erase ALL Special Program ModeLanguage SP-2 Mode Audio Volume SP-4System Initialization SP-3 Audio Tone SP-5Idle Mode SP-7 Type of shortening to be melted Liquid or Solid SP-6Mixed Press SP-8C shows in the display, if YES Special Program Schedule To filter the shortening. Press To changeClean-Out Temperature Sp-11 Product Buttons Sp-9 ModeClean-Out Temperature Sp-10 Mode Program Code Change SP-15 Usage Code Change SP-16Mode Shows in display If not satisfied with code, press Data LOGGING, Heat CONTROL, Tech MODE, and Stat ModeIf satisfied with code, press Code ChangePress to continue to Last Load Information Mode Last Load Function DisplayexInformation Mode Function Display EXOutp H* P Analog 1 OIL TMPCPU TMP