Henny Penny OFE- 291 manual Outp H* P

Page 39

Model OFE- 291

3-18. INFORMATION MODE Press to view the specific status of each input. An

(Continued)

underscore (“_”) indicates the input is not presently detected. A checkmark (“ ”) indicates the signal is detecting a normal input. Ablinking (“X”) indicates the signal is presently detected, but is detected as a half-wave (partially failed) input.

The V, H, D, S, F, P and M signals below are wired in series. The first signal missing out of this sequence generally causes all signals to the right of it to be missing as well.

Press to continue onto OUTP H* P_.

6. OUTP H* P_

This mode displays the status of components and outputs. If the output signal is detected, an identifying letter is displayed (see below), followed by an “*”. If the output is off, “_” is displayed.

“H” = Heat output

“P” = Pressure output (pressure fryers only) If heat is on, “H*” shows in display. If heat is off, “H_” shows in display. If controls senses a problem with the heat output, “H*” shows in display, with the “*” flashing.

If pressure is on, “P*” shows in display. If pressure is off, “P_” shows in display. If controls senses a problem with the pressure output, “P*” shows in display, with the “*” flashing.

Pressto view the amp “DRAW” status of each output. “H ” and “P ” in the display means the amps are good. A flashing “X” behind the H or P means too much current.

Press to view the No Connect/Ground (“NC/GND”) status of each output. This monitors a possible problem with the relays on the output PC board.

“H ” and “P ” in the display means everything on the output PC board is good. A flashing “X” behind the H or P means a problem exists.

Press to view the outputs and inputs (see step 10) together.

3-39

403

Image 39
Contents Operation Operating Components LID Operation Switches IndicatorsDescription Function Switches and Indicators Description Function Model OFE 403 Clock SET Clock SET Filling or Adding Shortening Product Racking Recommendations LINE. Failure to Follow These Instruc Above the Upper Frypot LevelindicatorBasic Operation Be Certain the Shortening is NeverAllow fryer to heat until Illuminates Unlatch and raise the lid cautiously Personal INJURY, FIRE, AND/OR Property Care ShorteningShortening Overflowingthe Frypot Which could Result in Serious BurnsFiltering Instructions Filtering Instructions Is in the OFF POSITION. ALSO, USE a DRY Rinse Hose When the Main Power SwitchFiltering Instructions Only Connectand Disconnect the FilterEnvelope Filter Pump Motor PROTECTOR-MANUAL Reset Cleaningthe Frypot Drained by slowly pulling the drain handle out towards you If hot shortening is present in the frypot, it must beDoes not boil over causing damage to controls Cleaning the FrypotPreventive Procedure FrequencyCleaning Nylatrons Monthly MaintenanceChange Product Names ProgrammingProgramming Filter Cycle Mode Optional ProgrammingGo to Idle after Done? Global Erase a Prod Preset a Prod Erase ALL Mode Special ProgramAudio Tone SP-5 Language SP-2 ModeAudio Volume SP-4 System Initialization SP-3Type of shortening to be melted Liquid or Solid SP-6 Idle Mode SP-7Mixed Press SP-8C shows in the display, if YES To filter the shortening. Press To change Special Program ScheduleProduct Buttons Sp-9 Mode Clean-Out Temperature Sp-10Clean-Out Temperature Sp-11 Usage Code Change SP-16 Mode Program Code Change SP-15Code Change Mode Shows in display If not satisfied with code, pressData LOGGING, Heat CONTROL, Tech MODE, and Stat Mode If satisfied with code, pressPress to continue to Last Load Function Displayex Information Mode Last LoadFunction Display EX Information ModeOutp H* P OIL TMP CPU TMPAnalog 1