Henny Penny OFE- 291 manual Programming, Change Product Names

Page 22

 

 

 

Model OFE- 291

3-15. PROGRAMMING

Change Product Names

 

 

(Continued)

a. Press and release

and the first letter, or digit,

 

starts flashing.

 

 

 

b. Press and release

to change the flashing letter.

 

c. To continue to the next letter, press

. Then press

 

to change this letter.

 

d.Repeat step c until up to 7 letters are entered.

e.Press and hold to exit Program Mode, or press and

releaseuntil “PRELOAD” shows in display, to continue with Program Mode.

5.The Preload Mode allows the operator to drop large pieces first, with the lid up, before loading the rest of the product. The preload cycle always regulates to the Step 1 cook

temperature. Press to set a pre-load time, or press

if no pre-load is desired

6. Press and release

and “1. COOK TIME” shows in the

display along with the preset time. Press

to change

the time. The time shows in minutes and seconds. Press and hold the buttons, and the time will jump by 5 second increments to a maximum of 59:59.

7.Press and release and “1. TEMP” shows in the display, along with the preset temperature on the right side

of the display. Pressto change the temperature. Press and hold the buttons and the temperature will jump by 5 degree increments to a max. of 380°F (193ºC), and a min. of 190°F (88ºC).

403

3-22

Image 22
Contents Operation Operating Components LID Operation Indicators SwitchesDescription Function Switches and Indicators Description Function Model OFE 403 Clock SET Clock SET Filling or Adding Shortening Product Racking Recommendations Be Certain the Shortening is Never Above the Upper Frypot LevelindicatorBasic Operation LINE. Failure to Follow These InstrucAllow fryer to heat until Illuminates Unlatch and raise the lid cautiously Which could Result in Serious Burns Care ShorteningShortening Overflowingthe Frypot Personal INJURY, FIRE, AND/OR PropertyFiltering Instructions Filtering Instructions Only Connectand Disconnect the Filter Rinse Hose When the Main Power SwitchFiltering Instructions Is in the OFF POSITION. ALSO, USE a DRYEnvelope Filter Pump Motor PROTECTOR-MANUAL Reset Cleaningthe Frypot If hot shortening is present in the frypot, it must be Drained by slowly pulling the drain handle out towards youCleaning the Frypot Does not boil over causing damage to controlsMaintenance Procedure FrequencyCleaning Nylatrons Monthly PreventiveProgramming Change Product NamesProgramming Programming Filter Cycle Mode OptionalGo to Idle after Done? Global Erase a Prod Preset a Prod Erase ALL Special Program ModeSystem Initialization SP-3 Language SP-2 ModeAudio Volume SP-4 Audio Tone SP-5Idle Mode SP-7 Type of shortening to be melted Liquid or Solid SP-6Mixed Press SP-8C shows in the display, if YES Special Program Schedule To filter the shortening. Press To changeClean-Out Temperature Sp-10 Product Buttons Sp-9 ModeClean-Out Temperature Sp-11 Mode Program Code Change SP-15 Usage Code Change SP-16If satisfied with code, press Mode Shows in display If not satisfied with code, pressData LOGGING, Heat CONTROL, Tech MODE, and Stat Mode Code ChangePress to continue to Last Load Information Mode Last Load Function DisplayexInformation Mode Function Display EXOutp H* P CPU TMP OIL TMPAnalog 1