Henny Penny OFE- 291 manual Mixed

Page 30

Model OFE- 291

3-16. SPECIAL PROGRAM

e. Change the idle setpoint temperature, by pressing

MODE (Continued)

f. Press and release

. “SP-7B” and

 

“AUTO-IDLE MINUTES” shows in the display, along with the preset time.

g.Press to set the minutes the cooker stays idle before theAuto-idle is enabled; 60 the maximum, OFF the minimum. Ex: “30” in the display means, if product is not cooked in that frypot for 30 minutes, the control automatically activates the idle setpoint temperature, programmed above.

h.Press and release . “SP-7C” and “GO IDLE AT MELT ?” shows in display.

i.Press to toggle from NO to YES, or vice versa. With “YES” in the display, the fryer automatically enters the Idle Mode once the Melt Mode is exited.

Filter Tracking Enabled (Sp-8)

The controls can be set to signal the operator when the shortening needs filtering. The Filter Tracking must be enabled to program the number of cook cycles between filtering procedures. (See Filter Cycles section 2-2.)

a.Follow steps 1 and 2 above.

b.Press and release until “SP-8”

and “FILTER TRACKING ENABLED” flashes on the display, along with “1,OFF”.

c. To enable the filter tracking, press to toggle the display from “1,OFF”, to “2,MIXED”, to, “3,GLOBAL”, or “4SCHED”.

The Mixed setting allows the operator to set different amounts of Cook Cycles between filters, for each product. If the operator wants to have one setting for all products go to step h.

MIXED

d. If “2,MIXED” is selected, press and “SP-8A” shows in the display followed by “SUGGEST FILTER AT …” and a value between 75% and 100%. Press and release

the to change this value.

e.Press and “SP-8B” shows in the display followed by “LOCKOUT ENABLED?” and “YES” or “NO”.

Press and release to choose yes or no.

1005

3-30

Image 30
Contents Operation Operating Components LID Operation Switches IndicatorsDescription Function Switches and Indicators Description Function Model OFE 403 Clock SET Clock SET Filling or Adding Shortening Product Racking Recommendations Be Certain the Shortening is Never Above the Upper Frypot LevelindicatorBasic Operation LINE. Failure to Follow These InstrucAllow fryer to heat until Illuminates Unlatch and raise the lid cautiously Which could Result in Serious Burns Care ShorteningShortening Overflowingthe Frypot Personal INJURY, FIRE, AND/OR PropertyFiltering Instructions Filtering Instructions Only Connectand Disconnect the Filter Rinse Hose When the Main Power SwitchFiltering Instructions Is in the OFF POSITION. ALSO, USE a DRYEnvelope Filter Pump Motor PROTECTOR-MANUAL Reset Cleaningthe Frypot If hot shortening is present in the frypot, it must be Drained by slowly pulling the drain handle out towards youCleaning the Frypot Does not boil over causing damage to controlsMaintenance Procedure FrequencyCleaning Nylatrons Monthly PreventiveProgramming Change Product NamesProgramming Filter Cycle Mode Optional ProgrammingGo to Idle after Done? Global Erase a Prod Preset a Prod Erase ALL Special Program ModeSystem Initialization SP-3 Language SP-2 ModeAudio Volume SP-4 Audio Tone SP-5Idle Mode SP-7 Type of shortening to be melted Liquid or Solid SP-6Mixed Press SP-8C shows in the display, if YES Special Program Schedule To filter the shortening. Press To changeProduct Buttons Sp-9 Mode Clean-Out Temperature Sp-10Clean-Out Temperature Sp-11 Mode Program Code Change SP-15 Usage Code Change SP-16If satisfied with code, press Mode Shows in display If not satisfied with code, pressData LOGGING, Heat CONTROL, Tech MODE, and Stat Mode Code ChangePress to continue to Last Load Information Mode Last Load Function DisplayexInformation Mode Function Display EXOutp H* P OIL TMP CPU TMPAnalog 1