Henny Penny OFE- 291 manual Switches, Indicators, Description Function

Page 3

 

 

 

 

Model OFE- 291

3-3.

SWITCHES AND

Refer to image at the end of this section.

 

INDICATORS

 

 

Fig.

Item

Description

Function

 

No.

No.

 

 

 

3-2

1

 

Lights when the control calls for heat; the elements come on and

 

 

 

heats the shortening

 

3-2

2

DigitalDisplay

Shows all the functions of the Cook Cycle, Program Modes,

 

 

 

Diagnostic Modes, and alarms

3-2

3

 

Only used on models that create pressure in the frypot; this

 

 

 

should not light

 

3-2

4

 

Flashes when the shortening temperature is not at the

 

 

 

proper temperature for cooking product

3-2

5

 

Lights when the shortening temperature is 5° F below to

 

 

 

15° F above the cooking temperature, signaling the operator

 

 

 

that the shortening temperature is at the proper temperature

 

 

 

for cooking product

 

3-2

6

 

Press to display the following fryer information and status:

 

 

 

a. The temperature of the shortening

 

 

 

b. The temperature setpoint

 

 

 

 

c. Filter status

 

 

 

 

d. The number of times filtered today

 

 

 

e. The average no. of filters per day

 

 

 

f. No. of times Cook Cycle was stopped early today

 

 

 

g. No. of times Cook Cycle was stopped early in past week

 

 

 

e. Oil Life Display (Only if “Change Oil” feature is enabled)

 

 

 

f. Date and time

 

 

 

 

If pressed in the Program Mode, shows previous settings.

 

 

 

Pressing this along with

accesses the Information

Mode which has historic information on the operator and fryer’s performance

3-2

7 & 8

Used to adjust the value of the currently displayed setting in

 

 

the Program Modes

1005

 

3-3

Image 3
Contents Operation Operating Components LID Operation Switches IndicatorsDescription Function Switches and Indicators Description Function Model OFE 403 Clock SET Clock SET Filling or Adding Shortening Product Racking Recommendations LINE. Failure to Follow These Instruc Above the Upper Frypot LevelindicatorBasic Operation Be Certain the Shortening is NeverAllow fryer to heat until Illuminates Unlatch and raise the lid cautiously Personal INJURY, FIRE, AND/OR Property Care ShorteningShortening Overflowingthe Frypot Which could Result in Serious BurnsFiltering Instructions Filtering Instructions Is in the OFF POSITION. ALSO, USE a DRY Rinse Hose When the Main Power SwitchFiltering Instructions Only Connectand Disconnect the FilterEnvelope Filter Pump Motor PROTECTOR-MANUAL Reset Cleaningthe Frypot Drained by slowly pulling the drain handle out towards you If hot shortening is present in the frypot, it must beDoes not boil over causing damage to controls Cleaning the FrypotPreventive Procedure FrequencyCleaning Nylatrons Monthly MaintenanceChange Product Names ProgrammingProgramming Filter Cycle Mode Optional ProgrammingGo to Idle after Done? Global Erase a Prod Preset a Prod Erase ALL Mode Special ProgramAudio Tone SP-5 Language SP-2 ModeAudio Volume SP-4 System Initialization SP-3Type of shortening to be melted Liquid or Solid SP-6 Idle Mode SP-7Mixed Press SP-8C shows in the display, if YES To filter the shortening. Press To change Special Program ScheduleProduct Buttons Sp-9 Mode Clean-Out Temperature Sp-10Clean-Out Temperature Sp-11 Usage Code Change SP-16 Mode Program Code Change SP-15Code Change Mode Shows in display If not satisfied with code, pressData LOGGING, Heat CONTROL, Tech MODE, and Stat Mode If satisfied with code, pressPress to continue to Last Load Function Displayex Information Mode Last LoadFunction Display EX Information ModeOutp H* P OIL TMP CPU TMPAnalog 1