Connecting the Appliance
Have a technician install and connect the appliance according to the enclosed Installation Instructions.
Do not remove the transportation protection devices from the shelves and storage compartments until the appliance has been installed.
Always connect the water before the power.
Apart from statutory national regulations, you should comply with all applicable local electricity and water companies codes and requirements.
After installing the appliance, wait at least 1 hour before switching the appliance On. During transportation the oil in the compressor may have flowed into the refrigeration system.
Before switching the appliance On for the first time, clean the interior of the appliance (see chapter “Cleaning the Appliance”).
Water Connection
,CAUTION:
Connect the appliance to a drinking water line only:
▯Minimum pressure: 0.2 Mpa (2 bar)
▯Maximum pressure: 0.8 Mpa (8 bar)
▯Pressure over 0.8 MPa (8 bar): install a pressure
limiter between drinking water connection and hose set:
The water may be connected only by a competent fitter according to the local regulations of the appropriate Water Supply company.
A cold water connection is necessary for operating the automatic Ice Maker. The water pressure must be between 29 and 116 p.s.i. (2.0 and 8.0 bar). The installation must correspond to the local plumbing regulations.
Install a separate
The
When installing the water connection, observe the permitted installation areas for the water line.
For connection to the drinking water mains use only water pipes which are suitable for drinking water. Observe national regulations and the connection conditions of the local Water Supply companies.
Electrical Connection
,WARNING:
Avoid the risk of an electric shock!
,WARNING:
Insert into a grounded
,WARNING:
the appliance has been grounded properly, have the appliance tested by a qualified electrician or service technician.
Do not use extensions or distributors.
The receptacle must be installed according to the Installation Manual.
The appliance complies with protection class I. Connect the appliance to 115 V/60 Hz AC through
acorrectly installed
The appliance comes with a UL registered
Please see the following table:
Appliance | Maximum Simultaneous Load |
Freezer 18“ | 3.5 amps |
|
|
Freezer 24“ | 4.0 amps |
|
|
Freezer 30“ | 4.5 amps |
|
|
Check on the Rating Plate whether the indicated voltage and current type correspond with the values of your power supply. The location of the Rating Plate can be found in the chapter “Customer Service”.
,WARNING:
Never connect the appliance to electronic energy saving devices.
Our appliances can be used with power line and sine- controlled inverters. Power
are connected directly to the national grid. Sine- controlled inverters must be used for isolated applications (e.g. on ships or in mountain lodges) which are not connected directly to the national grid.
7