DCS 36/48BGB manual LP Tank Requirements, LP Gas

Page 15

INSTALLATION

GAS HOOK-UP

Connection: 1/2” NPT male with a 3/8” Flare adapter (included). LP Hose with a quick disconnect and fittings are

included. Operating pressure: 11.0” W.C.

Note: All gas piping and connectors must conform to the Standard for Connectors for Outdoor Gas Appliances and Manufactured Homes, ANSI Z21.75/CSA 6.27.

CAUTION!

Before connecting LP tank to regulator, check that all grill burners and side burners, smokers, and rotisserie valves are in the OFF position and open grill lid.

To connect the LP regulator/hose assembly to the tank/valve assembly, first make sure the main valve on the tank is completely closed. Although the flow of gas is stopped when the Type 1 system is disconnected as part of of its safety feature, you should always turn off the LP tank main valve (Fig. 09) after each use and during transport of the tank or unit. Insert the regulator inlet into the tank valve and turn to the black coupler clockwise until the coupler tightens up. Do not overtighten the coupler. Turn the main tank valve on and turn the burner control valves on the unit to the “HI” position for about 20 seconds to allow the air in the system to purge, turn valves off and wait 5 minutes before attempting to light the burners.

To disconnect the coupler, first make sure the main tank valve is turned off. Grasp the coupler and turn counter clockwise. The inlet will then disengage. Remove the inlet from the tank valve opening if it has not already done so when it disengaged. Your local LP filling station should be equipped with the proper equipment to fill your tank.

LP TANK REQUIREMENTS:

A dented or rusty LP tank may be hazardous and should be checked by your LP supplier. The cylinder that is used must have a collar to protect the cylinder valve. Never use a cylinder with a damaged valve. Always check for leaks after every LP tank change. The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (DOT or CAN/CSA-B339) and de- signed for use with a Type 1 system only. Do not change the regulator/hose assembly from that supplied with the unit or attempt to use a Type 1 equipped regulator/hose assembly with a standard 510 POL tank/valve assembly. The cylinder must be provided with a shut-off valve terminating in an LP gas supply cylinder valve outlet speci- fied, as applicable, for connection Type 1. If the appliance is stored indoors, the cylinder must be disconnected and removed from the appliance. Cylinders must be stored outdoors in a well-ventilated area out of the reach of children.

Note:

When an LP unit is being directly connected to an LP house system, you must follow the natural gas hook up guidelines. The installer must provide the proper gas regulator to reduce the gas pressure to 11” W.C.

The Grill comes with the LP Gas Regulator/Hose assembly installed at the factory. The assembly, along with the entire Grill system, is leak tested. Do not remove the Regulator/Hose

assembly from the Grill during installation.

WARNING :

 

Bottom of unit

1. Do not remove the Grill from the pallet until you are

 

 

 

ready to install.

Type 1 Regulator

Elbow 45º

2. Do not place the Grill directly on the ground or any other

Main Tank Valve

1/2” female

 

NPT x 3/8” male flare

flat surface without support. This will prevent damaging

 

(installed on the unit)

 

 

the regulator/hose assembly by the weight of the grill.

 

LP Regulator hose

 

 

3. Check the hose, regulator and connectors for damage.

 

assembly 11" W.C.

 

 

Look for cracks, abrasions, brittleness, holes, dents and

20/30 lb. LP Tank

*Installation must conform with

nicks.

 

local codes or with the National

 

Fuel Gas Code ANSI Z223.1 or the

4. Do not attempt to remove, repair, or replace the Regu-

 

CAN/CGA-B149.2 Propane

 

Installation Code

 

 

lator/Hose assembly by yourself. It must be done by a

 

FIG. 09 LP Gas

qualified licensed technician only.

 

 

13

Image 15
Contents User guide Page Please Retain this Manual for Future Reference Message to OUR CustomersTable of Contents Important Safety Notice Safety Practices & PrecautionsAIR Flow Grill PlacementSafety Practices & Precautions Grill Models Installation Locating GRILL/BUILT-IN ClearancesLocation Clearances to Non-Combustible Construction Clearances to Non-Combustible ConstructionClearances to Combustible Construction GeneralInsulated Jacket BUILT-IN Construction Details Access Drawers Cutout dimensions GAS HOOK-UP LP Gas LP Tank RequirementsCenter of manifold cut out projected to floor of the island LP Tank Restraint for BUILT-IN InstallationStep Leak Testing Before TestingTo Test Grill Burner Flame Height Burner AdjustmentGrill Burner AIR Adjustment LOW Flame Setting AdjustmentRadiant Asssembly Installation Radiant AssemblyInstaller Checklist To Light Dual Side Burners 48BQR Models only Using the GrillLighting Instructions To Light the Grill BurnerBurner Off GrillingGrill DIRECT/INDIRECT Cooking NotesGrilling Hints DUAL-SIDED GratesShaped Grate Radius Grate Using the Smoker System To Light the Smoker BurnerWood Chips Using the Rotisserie Meat Preparation PreparationRecommended Working AreaManual Lighting To Light the Rotisserie Burner Before CookingCooking on Rotisserie Care and Maintenance Stainless Steel To Remove the U-BURNERS for CleaningGrill Burner Cleaning Orifice CleaningSmoker Burner Side Burners BGB48 BQR ModelLOW Heat with Knob in HI/SEAR Position TroubleshootingBefore Calling for Service Grill WON’T Light When the Ignition Button is PushedHOW to Obtain Service ServiceThis Warranty does not Cover WarrantyLimited Warranty HOW Long does the Limited Warranty LAST?HOW to GET Service Commercial USENo Other Warranties Page Page Veuillez Conserver CE Manuel À Titre DE Référence ’INTENTION DE NOS ClientsTable DES Matières Autocollant Mesures DE Sécurité ET DE PrécautionDe ventilation Flux Dair Préféré Emplacement DU GrilRemarque Modèles DE Gril Emplacement Emplacement DU Gril ET DES DégagementsEspaces de dégagement pour une construction non combustible Enveloppe Isolée GénéralitésDisposition standard pour une enceinte non combustible Détails D’UNE Construction IntégréeModèle Pour Connecter LES Raccords Fournis Avec LE Gril Branchement DU GAZExigences Concernant LE GAZ Branchement DU GAZ NaturelExigences Concernant LA Bouteille DE Propane Mise EN GardeRemarque Placez le dispositif de retenue de bouteille dans l’îlot Fig Test DE Détection DES Fuites Avant la vérificationPour tester Réglages Pour Niveau BAS Réglages DES BrûleursRéglage D’AIR DU Brûleur DU Gril Hauteur DES Flammes DU Brûleur DU GrilInstallation DE L’ENSEMBLE DU Radiant Installation DE L’ENSEMBLE DU RadiantListe DE Contrôle DE L’INSTALLATEUR Allumage du gril à l’allumette Utilisation DU GrilInstructions D’ALLUMAGE Pour Allumer LE Brûleur DU GrilGril Instructions D’ALLUMAGE/CUISSON SUR GrilAllumage des brûleurs latéraux avec une allumette Brûleurs latérauxConseils AU Sujet DU Gril Cuisson SUR GrilGrille EN Forme DE « W » Grille Arondie Grilles Double FaceUtilisation DU Système À Fumoir Pour Allumer LE Brûleur À FumoirCopeaux DE Bois Utilisation DE LA Rôtissoire Préparation RecommandéAllumage Manuel Pour Allumer LE Brûleur DE Rôtisserie Avant DE Faire CuireCuisson SUR LA Rôtissoire Entretien ET Nettoyage Déposer DES Brûleurs EN U Pour LE Nettoyage Acier InoxydableÉlectrodes Brûleur DU GrilBrûleurs Latéraux BGB48 BQR ModeleBrûleur À Fumoir LA Rôtissoire NE S’ALLUME PAS Avant D’APPELER LE Service TechniqueDépannage Chaleur Faible Avec LE Bouton EN Position « SEAR/HI »Pour L’OBTENTION DU Service DE Garantie Quelle EST LA Durée DE LA Garantie LIMITÉE? GarantieGarantie Limitée Fisher & Paykel S’ENGAGE ÀPour Obtenir DES Réparations Utilisation CommercialeAucune Autre Garantie Remarque US CA