LEAK TESTING

GENERAL:

Although all gas connections on the grill are leak tested at the factory prior to shipment, a complete gas tightness check must be performed at the installation site due to possible mishandling in shipment, or excessive pressure unknowingly being applied to the unit. Periodically check the whole system for leaks, or immediately check if the smell of gas is detected.

Before Testing:

Do not smoke while leak testing. Extinguish all open flames. Never leak test with an open flame. Make a soap solution of one part liquid detergent and one part water. You will need a spray bottle, brush, or rag to apply the solution to the fittings. For LP units, check with a full cylinder. The valve panel must be removed to check the valves and fittings. Remove the knobs and the safety valve knob, then remove the 2 screws which fasten the valve panel to the unit (you will need a Philips screw driver for this). Pull the valve panel outward and unplug the wires from the ignition module and the back of the ignition button. In the back of the unit remove the screws which hold the service panel in place. Remove the service panel.

To Test:

Make sure all control valves are in the “OFF” position. Turn the gas supply “ON”. Check all connections from the supply line, or LP cylinder up to and including the manifold pipe assembly. Apply the soap solution around the connection, valve, tubing and end of the manifold. Soap bubbles will appear where a leak is present. If a leak is present, immediately turn off gas supply, tighten any leaking connections, turn gas on, and recheck. Check all the gas connections at the base of the control valves where they screw into the manifold pipe.

To check rotisserie burner and safety valve the burner must be lit, then leak test the connections located behind the service panel. If you cannot stop a gas leak turn off the gas supply and call your local gas utility, or the dealer you purchased the appliance from. Only those parts recommended by the manufacturer should be used on the grill. Substitution can void the warranty.

WARNING!

Do not use the grill until all connections have been checked and do not leak.

Check all gas supply fittings for leaks before each use. Keep a spray bottle of soapy water near the gas supply shut-off valve. Spray all the fittings. Bubbles indicate leaks (Fig. 16 & 17).

Bottom of unit

LEAK TEST POINTS

CHECK HOSE FOR SIGNS OF ABRASIONS, CRACKS, OR LEAKS

LP TANK

Bottom of unit

LEAK TEST POINTS

FIG. 16 LP Gas

FIG. 17 Nat. Gas

16

Image 18
Contents User guide Page Message to OUR Customers Please Retain this Manual for Future ReferenceTable of Contents Safety Practices & Precautions Important Safety NoticeGrill Placement AIR FlowSafety Practices & Precautions Grill Models Installation Locating GRILL/BUILT-IN ClearancesLocation Clearances to Non-Combustible Construction Clearances to Non-Combustible ConstructionClearances to Combustible Construction GeneralInsulated Jacket BUILT-IN Construction Details Access Drawers Cutout dimensions GAS HOOK-UP LP Tank Requirements LP GasLP Tank Restraint for BUILT-IN Installation Center of manifold cut out projected to floor of the islandStep Leak Testing Before TestingTo Test LOW Flame Setting Adjustment Burner AdjustmentGrill Burner AIR Adjustment Grill Burner Flame HeightRadiant Assembly Radiant Asssembly InstallationInstaller Checklist To Light the Grill Burner Using the GrillLighting Instructions To Light Dual Side Burners 48BQR Models onlyDIRECT/INDIRECT Cooking Notes GrillingGrill Burner OffGrilling Hints DUAL-SIDED GratesShaped Grate Radius Grate Using the Smoker System To Light the Smoker BurnerWood Chips Using the Rotisserie Working Area PreparationRecommended Meat PreparationTo Light the Rotisserie Burner Before Cooking Manual LightingCooking on Rotisserie Care and Maintenance Orifice Cleaning To Remove the U-BURNERS for CleaningGrill Burner Cleaning Stainless SteelSide Burners BGB48 BQR Model Smoker BurnerGrill WON’T Light When the Ignition Button is Pushed TroubleshootingBefore Calling for Service LOW Heat with Knob in HI/SEAR PositionService HOW to Obtain ServiceHOW Long does the Limited Warranty LAST? WarrantyLimited Warranty This Warranty does not CoverHOW to GET Service Commercial USENo Other Warranties Page Page ’INTENTION DE NOS Clients Veuillez Conserver CE Manuel À Titre DE RéférenceTable DES Matières Mesures DE Sécurité ET DE Précaution AutocollantDe ventilation Emplacement DU Gril Flux Dair PréféréRemarque Modèles DE Gril Emplacement DU Gril ET DES Dégagements EmplacementEspaces de dégagement pour une construction non combustible Généralités Enveloppe IsoléeDétails D’UNE Construction Intégrée Disposition standard pour une enceinte non combustibleModèle Branchement DU GAZ Naturel Branchement DU GAZExigences Concernant LE GAZ Pour Connecter LES Raccords Fournis Avec LE GrilMise EN Garde Exigences Concernant LA Bouteille DE PropaneRemarque Placez le dispositif de retenue de bouteille dans l’îlot Fig Test DE Détection DES Fuites Avant la vérificationPour tester Hauteur DES Flammes DU Brûleur DU Gril Réglages DES BrûleursRéglage D’AIR DU Brûleur DU Gril Réglages Pour Niveau BASInstallation DE L’ENSEMBLE DU Radiant Installation DE L’ENSEMBLE DU RadiantListe DE Contrôle DE L’INSTALLATEUR Pour Allumer LE Brûleur DU Gril Utilisation DU GrilInstructions D’ALLUMAGE Allumage du gril à l’allumetteBrûleurs latéraux Instructions D’ALLUMAGE/CUISSON SUR GrilAllumage des brûleurs latéraux avec une allumette GrilCuisson SUR Gril Conseils AU Sujet DU GrilGrilles Double Face Grille EN Forme DE « W » Grille ArondieUtilisation DU Système À Fumoir Pour Allumer LE Brûleur À FumoirCopeaux DE Bois Utilisation DE LA Rôtissoire Recommandé PréparationPour Allumer LE Brûleur DE Rôtisserie Avant DE Faire Cuire Allumage ManuelCuisson SUR LA Rôtissoire Entretien ET Nettoyage Brûleur DU Gril Acier InoxydableÉlectrodes Déposer DES Brûleurs EN U Pour LE NettoyageBrûleurs Latéraux BGB48 BQR ModeleBrûleur À Fumoir Chaleur Faible Avec LE Bouton EN Position « SEAR/HI » Avant D’APPELER LE Service TechniqueDépannage LA Rôtissoire NE S’ALLUME PASPour L’OBTENTION DU Service DE Garantie Fisher & Paykel S’ENGAGE À GarantieGarantie Limitée Quelle EST LA Durée DE LA Garantie LIMITÉE?Pour Obtenir DES Réparations Utilisation CommercialeAucune Autre Garantie Remarque US CA