Blodgett XR8-G manual Utility Connections --- Standards and Codes

Page 10

Installation

Utility Connections --- Standards and Codes

THE INSTALLATION INSTRUCTIONS CONTAINED HEREIN ARE FOR THE USE OF QUALIFIED IN- STALLATION AND SERVICE PERSONNEL ONLY. INSTALLATION OR SERVICE BY OTHER THAN QU- ALIFIED PERSONNEL MAY RESULT IN DAMAGE TO THE OVEN AND/OR INJURY TO THE OPERA- TOR.

Qualified installation personnel are individuals, a firm, a corporation, or a company which either in person or through a representative are engaged in, and responsible for:

Dthe installation or replacement of gas piping and the connection, installation, repair or serv- icing of equipment.

Dthe installation of electrical wiring from the elec- tric meter, main control box or service outlet to the electric appliance.

Qualified installation personnel must be experi- enced in such work, familiar with all precautions required, and have complied with all requirements of state or local authorities having jurisdiction.

U.S. and Canadian installations

Installation must conform with local codes, or in the absence of local codes, with the ANSI Z83.11a- CSA 1.8a-2004 Gas Food Service Equipment as applicable.

Installation must conform with local codes, or in the absence of local codes, with the National Elec- trical Code, ANSI/NFPA 70 ---Latest Edition and/or CSA 22.1 as applicable.

General export installations

Installation must conform with Local and National installation standards. Local installation codes and/or requirements may vary. If you have any questions regarding the proper installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local dis- tributor, please call the Blodgett Oven Company at 0011-802-860-3700.

6

Image 10
Contents XR8-G Avertissement Reputation YOU can Count on Page Table of Contents/Table des Matières Plumbing Specifications -- XR8-G/AA Oven Description and SpecificationsGAS Specifications -- XR8-G/AA IntroductionDelivery and Inspection InstallationDelivery and Location Oven LocationAssembly to Stand Oven AssemblyAssembly to Optional Proofer Ventilation Canadian installationsGeneral export installations Canopy Type Exhaust HoodUtility Connections --- Standards and Codes Gas Connection GAS PipingKPa Manifold Pressure Natural Propane Pressure Regulation and TestingInlet Pressure Natural Propane KPaGAS Hose Restraint Plumbing Connections Electrical SpecificationsPlumbing and Electrical Connections Electrical ConnectionsAdjustments Associated with Initial Installation Initial StartupWhat to do in the event of a power failure Safety InformationSafety Tips General safety tipsSolid State Digital Control Control DescriptionStandard Control OperationGeneral Guidelines for Operating Personnel Operating TipsCleaning the Oven MaintenanceCleaning and Preventative Maintenance Preventative MaintenanceTroubleshooting Guide Possible Causes Suggested RemedyGaz Naturel Gaz Propane Unités US Unités SI Specifications Pour GAZ -- XR8-G/AADescription et Spécifications du Four Spécifications DE Plomberie -- XR8-G/AALivraison ET Inspection Livraison et ImplantationImplantation DU Four Assemblage SUR UN Stand Montage du FourAssemblage SUR UNE Étuve DE FER- Mentation Optionnelle Avertissement Installation aux États-Unis et au CanadaGénéralités concernant les installations à l’ex- portation Hotte D’ÉVACUATION Type VoûteBranchements de Service --- Normes et Codes Généralités concernant les installations à l’exportationConduit DE GAZ Longeur Dimensions nominales De conduit PiedsBranchement de Gaz ExemplePression à l’entrée Gaz Naturel Gaz Propane Réglage ET Test DE PressionKPa Pression au collecteur Gaz Naturel Gaz Propane Retenue DU Tuyau DE GAZ Raccordements de purge Raccordement Électrique et PlomberieRaccordement Plomberie Avertissement Raccordement ÉlectriqueRéglages À Faire Lors DE L’INSTALLA- Tion Initiale Mise en Marche InitialeConseils DE Sécurité UtilisationInformations de Sécurité Que faire en cas de panne de secteurCommande Classique Description DES CommandesUtilisation Consignes Générales à l’Intention des Utilasateurs ConseilsEntretien Maintenance PreventiveMaintenance annuelle Nettoyage et Entretien PréventifGuide de Détection des Pannes Causes Probables SuggestionGuide de Détection des Pannes Insert Wiring Diagram Here Placer Schéma DE Câblage ICI