| Maintenance | ||
|
|
|
|
|
|
|
|
|
|
| Troubleshooting Guide | ||
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| POSSIBLE CAUSE(S) |
| SUGGESTED REMEDY |
|
|
|
|
|
|
|
|
|
|
| SYMPTOM: Oven will not fire. |
|
|
|
|
|
|
|
|
|
| |
| S | Gas turned off. | S | Turn the gas valve to ON. |
|
|
| S | Oven not plugged in. | S | Plug in electrical supply cord. |
| |
| S | Power switch on the control panel is off. | S | Set the control panel to ON. |
| |
| S | Control set below ambient temperature. | S | Set to desired cook temperature. |
| |
| S | Doors are open. | S | Close doors. |
| |
| S | No draft on the burner. | S | Check draft inducer opening. |
| |
|
|
|
|
|
|
|
|
| SYMPTOM: Oven does not come to ready. |
|
|
|
|
|
|
|
|
| ||
| S The oven has not reached preheat temperature. | S | Wait for oven to reach preheat temperature. |
|
| |
| S | Gas valve not turned on completely. | S | Check the gas valve, turn on fully if necessary. |
| |
| S | The quick disconnect is not connected. | S Reconnect the quick connect. Check all gas |
| ||
|
|
|
| connections. |
| |
| S | Gas pressure to oven is too low. | S | Call your local gas representative. |
| |
| S Internal problem with main temperature control. | S | * |
|
| |
|
|
|
|
|
|
|
|
| SYMPTOM: Convection fan does not run. |
|
|
|
|
|
|
|
|
|
| |
| S | Oven is not plugged in. | S | Plug in electrical supply cord. |
|
|
| S | Circuit breaker tripped. | S | Reset the breaker. |
| |
| S | Doors are open | S | Close doors. |
| |
| S | Blower delay was set. | S | Reset blower delay time. |
| |
|
|
|
|
|
|
|
|
| SYMPTOM: General baking problems. |
|
|
|
|
|
|
|
|
|
|
|
| S | Thermostat out of calibration. | S | * |
|
|
| S | Improper oven venting. | S | * |
|
|
|
|
|
|
| ||
|
| SYMPTOM: Rack does not stop rotating after doors are opened or rack stops in wrong position. |
|
| ||
|
|
|
|
|
| |
| S | Rack rotator switch out of position | S | Reposition rack rotator switch |
|
|
|
|
|
| |||
| *Denotes remedy is a difficult operation and should be performed by qualified personnel only. It is recommended, however, that |
|
| |||
| All repairs and/or adjustments be done by your local Blodgett service agency and not by the owner/operator. Blodgett cannot as- |
| ||||
| sume responsibility for damage as a result of servicing done by unqualified personnel. |
| ||||
|
|
|
|
|
|
|
WARNING!!
Always disconnect the power supply before cleaning or servicing the oven.
17