Blodgett XR8-G manual Pressure Regulation and Testing, Inlet Pressure Natural Propane, KPa

Page 12

Installation

Gas Connection

PRESSURE REGULATION AND TESTING

XR8-G ovens are rated at 110,000 BTU/Hr. (32 kW) (116 MJ/hr). Each oven has been adjusted at the factory to operate with the type of gas specified on the rating plate.

Inlet Pressure

 

Natural

Propane

 

 

 

 

 

 

 

 

Min

 

Max

Min

 

Max

 

 

 

 

 

 

 

W.C.

6.0

 

14.0

11.0

 

14.0

 

 

 

 

 

 

 

kPa

1.2

 

3.5

2.7

 

3.5

 

 

 

 

 

 

Manifold Pressure

 

 

 

 

 

 

 

Natural

Propane

 

 

 

 

 

W.C.

 

3.5

 

10.0

 

 

 

 

 

kPa

 

.87

 

2.5

DInlet Pressure --- the pressure of the gas before it reaches the oven.

DManifold Pressure --- the pressure of the gas as it enters the main burner(s).

DMin --- the minimum pressure recommended to operate the oven.

D Max --- the maximum pressure at which the manufacturer warrants the oven’s operation.

Each oven is supplied with a regulator to maintain the proper gas pressure. The regulator is essen- tial to the proper operation of the oven and should not be removed. It is preset to provide the oven with 3.5” W.C. (.87 kPa) for natural gas and 10.0” W.C. (2.5 kPa) for Propane at the manifold.

DO NOT INSTALL AN ADDITIONAL REGULATOR WHERE THE OVEN CONNECTS TO THE GAS SUPPLY UNLESS THE INLET PRESSURE IS ABOVE MAXIMUM.

Prior to connecting the oven, gas lines should be thoroughly purged of all metal filings, shavings, pipe dope, and other debris. After connection, the oven should be checked for correct gas pressure.

The oven and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.45kPa).

The oven must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas piping system at test pressures equal or less than 1/2 psig (3.45kPa).

Gas Connection

 

2.78” (71 mm)

 

 

53.62 (1362)

 

Gas Connection

 

37.83 (961mm)

 

Gas Connection

SIDE VIEW WITH STAND

SIDE VIEW WITH OPTIONAL PROOFER

Figure 2

8

Image 12
Contents XR8-G Avertissement Reputation YOU can Count on Page Table of Contents/Table des Matières Oven Description and Specifications GAS Specifications -- XR8-G/AAPlumbing Specifications -- XR8-G/AA IntroductionInstallation Delivery and LocationDelivery and Inspection Oven LocationOven Assembly Assembly to StandAssembly to Optional Proofer Canadian installations General export installationsVentilation Canopy Type Exhaust HoodUtility Connections --- Standards and Codes Gas Connection GAS PipingPressure Regulation and Testing Inlet Pressure Natural PropaneKPa Manifold Pressure Natural Propane KPaGAS Hose Restraint Electrical Specifications Plumbing and Electrical ConnectionsPlumbing Connections Electrical ConnectionsAdjustments Associated with Initial Installation Initial StartupSafety Information Safety TipsWhat to do in the event of a power failure General safety tipsSolid State Digital Control Control DescriptionStandard Control OperationGeneral Guidelines for Operating Personnel Operating TipsMaintenance Cleaning and Preventative MaintenanceCleaning the Oven Preventative MaintenanceTroubleshooting Guide Possible Causes Suggested RemedySpecifications Pour GAZ -- XR8-G/AA Description et Spécifications du FourGaz Naturel Gaz Propane Unités US Unités SI Spécifications DE Plomberie -- XR8-G/AALivraison et Implantation Livraison ET InspectionImplantation DU Four Montage du Four Assemblage SUR UN StandAssemblage SUR UNE Étuve DE FER- Mentation Optionnelle Installation aux États-Unis et au Canada Généralités concernant les installations à l’ex- portationAvertissement Hotte D’ÉVACUATION Type VoûteBranchements de Service --- Normes et Codes Généralités concernant les installations à l’exportationLongeur Dimensions nominales De conduit Pieds Branchement de GazConduit DE GAZ ExempleRéglage ET Test DE Pression Pression à l’entrée Gaz Naturel Gaz PropaneKPa Pression au collecteur Gaz Naturel Gaz Propane Retenue DU Tuyau DE GAZ Raccordement Électrique et Plomberie Raccordement Plomberie AvertissementRaccordements de purge Raccordement ÉlectriqueRéglages À Faire Lors DE L’INSTALLA- Tion Initiale Mise en Marche InitialeUtilisation Informations de SécuritéConseils DE Sécurité Que faire en cas de panne de secteurCommande Classique Description DES CommandesUtilisation Consignes Générales à l’Intention des Utilasateurs ConseilsMaintenance Preventive Maintenance annuelleEntretien Nettoyage et Entretien PréventifGuide de Détection des Pannes Causes Probables SuggestionGuide de Détection des Pannes Insert Wiring Diagram Here Placer Schéma DE Câblage ICI