Blodgett XR8-G manual GAS Hose Restraint, General export installations

Page 13

Installation

Gas Connection

GAS HOSE RESTRAINT

If the oven is mounted on casters, a commercial flexible connector with a minimum of 3/4” (1.9 cm) inside diameter must be used along with a quick connect device.

The restraint, supplied with the oven, must be used to limit the movement of the unit so that no strain is placed upon the flexible connector. With the restraint fully stretched the connector should be easy to install and quick connect.

The restraint (ie: heavy gauge cable) should be 1,000 lb. (453 kg) test load and should be attached without damaging the building. DO NOT use the gas piping or electrical conduit for the attachment of the permanent end of the restraint! Use anchor bolts in concrete or cement block. On wooden walls, drive hi test wood lag screws into the studs of the wall.

1.Mount the supplied bracket to the leg bolt be- low the gas inlet. See Figure 3.

2.Attach the clip on restraining cable to the mounting bracket.

Back of Oven

Restraint Cable

Bracket

WARNING!!

If the restraint is disconnected for any reason it must be reconnected when the oven is returned to its original position.

U.S. and Canadian installations

The connector must comply with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69S CSA 6.16 and a quick disconnect device that complies with the Standard for Quick-Discon- nect Devices for Use With Gas Fuel, ANSI Z21.41S CSA 6.9. Adequate means must be provided to

limit the movement of the appliance without de- pending on the connection and the quick discon- nect device or its associated piping.

General export installations

The restraint and quick connect must conform with Local and National installation standards. Lo- cal installation codes and/or requirements may vary. If you have any questions regarding the prop- er installation and/or operation of your Blodgett oven, please contact your local distributor. If you do not have a local distributor, please call the Blodgett Oven Company at 0011-802-860-3700.

Figure 3

9

Image 13
Contents XR8-G Avertissement Reputation YOU can Count on Page Table of Contents/Table des Matières GAS Specifications -- XR8-G/AA Oven Description and SpecificationsPlumbing Specifications -- XR8-G/AA IntroductionDelivery and Location InstallationDelivery and Inspection Oven LocationAssembly to Stand Oven AssemblyAssembly to Optional Proofer General export installations Canadian installationsVentilation Canopy Type Exhaust HoodUtility Connections --- Standards and Codes GAS Piping Gas ConnectionInlet Pressure Natural Propane Pressure Regulation and TestingKPa Manifold Pressure Natural Propane KPaGAS Hose Restraint Plumbing and Electrical Connections Electrical SpecificationsPlumbing Connections Electrical ConnectionsInitial Startup Adjustments Associated with Initial InstallationSafety Tips Safety InformationWhat to do in the event of a power failure General safety tipsControl Description Solid State Digital ControlOperation Standard ControlOperating Tips General Guidelines for Operating PersonnelCleaning and Preventative Maintenance MaintenanceCleaning the Oven Preventative MaintenancePossible Causes Suggested Remedy Troubleshooting GuideDescription et Spécifications du Four Specifications Pour GAZ -- XR8-G/AAGaz Naturel Gaz Propane Unités US Unités SI Spécifications DE Plomberie -- XR8-G/AALivraison ET Inspection Livraison et ImplantationImplantation DU Four Assemblage SUR UN Stand Montage du FourAssemblage SUR UNE Étuve DE FER- Mentation Optionnelle Généralités concernant les installations à l’ex- portation Installation aux États-Unis et au CanadaAvertissement Hotte D’ÉVACUATION Type VoûteGénéralités concernant les installations à l’exportation Branchements de Service --- Normes et CodesBranchement de Gaz Longeur Dimensions nominales De conduit PiedsConduit DE GAZ ExemplePression à l’entrée Gaz Naturel Gaz Propane Réglage ET Test DE PressionKPa Pression au collecteur Gaz Naturel Gaz Propane Retenue DU Tuyau DE GAZ Raccordement Plomberie Avertissement Raccordement Électrique et PlomberieRaccordements de purge Raccordement ÉlectriqueMise en Marche Initiale Réglages À Faire Lors DE L’INSTALLA- Tion InitialeInformations de Sécurité UtilisationConseils DE Sécurité Que faire en cas de panne de secteurDescription DES Commandes Commande ClassiqueUtilisation Conseils Consignes Générales à l’Intention des UtilasateursMaintenance annuelle Maintenance PreventiveEntretien Nettoyage et Entretien PréventifCauses Probables Suggestion Guide de Détection des PannesGuide de Détection des Pannes Insert Wiring Diagram Here Placer Schéma DE Câblage ICI