Garland Salamander Broiler General Information, Installation, National Code Requirements

Page 6

GENERAL INFORMATION

The range-mounted, gas Infra-Red Salamander Broiler is designed for a perfect match and fit to the US Range U series Range..

Garland/US Range products are not approved or authorized for home or residential use, but are intended for commercial applications only.. Garland/US Range will not provide service, warranty, maintenance or support of any kind other than in commercial applications..

Salamander Performance and Construction

Two Hi-Low gas valves provide individual control of the (2) atmospheric-type 20,000 BTU/Hr gas infra-red burners for the Salamander.. The“LO” position is adjustable for most field gas pressure situations.. Fast preheat and uniform production is provided by the high-efficiency, infra-red burners.. The unique atmospheric design eliminates the need for fans and filters.. Heat is directed downward to the large -380 square inch plus – heavy duty broiling rack.. The rack is easily removed from the spring balanced rack assembly.. The rack assembly rolls out for ease of loading and unloading and, raises and lowers with positive locking in three positions.. The full-width grease deflector attached to the underside of the rack assembly channels hot drippings to a large capacity drip tray even when the rack assembly is rolled out.. The rack assembly and drip pan are easily removed for cleaning..

Models UIR36 and UIR48 salamanders are 36” (900mm) and 48” (1200 mm) wide respectively and are supported by heavy-formed brackets to mount to the range..

Model UIR60 mounts to a 60” (1500mm) wide U Series range and includes a 24” (600mm) wide shelf..

Model UIR36C is a counter unit and comes equipped with 4” (102mm) stainless steel legs, it may be mounted to a wall with an optional wall mounting kit..

All salamander models have a stainless steel top and sides.. Stainless steel bottoms and heat shields are standard on range match models, optional on model GIR36C

INSTALLATION

This product has been certified as commercial cooking equipment and must be installed by professional personnel as specified.. THIS APPLIANCE IS NOT RECOMMENDED FOR RESIDENTIAL INSTALLATION..

We suggest installation, maintenance and repairs be preformed by your local Garland/US Range authorized service agency..

National Code Requirements

The importance of the proper installation of Commercial Gas Cooking Equipment cannot be over stressed.. Proper performance of the equipment is dependent, in great part, on the compliance of the installation with the manufacturer’s specifications.. Installation must conform to local codes

or, in the absence of local codes, with the National Fuel Gas Code, NFPA54 / ANSI Z223..1 or latest edition, Natural Gas Installation Code, CAN/GCA-B149..1 or the Propane Installation Code, CAN/CGA-B149..2 or latest editions, as applicable..

Page

Part # 4523974 (11/07)

Image 6
Contents Installation Operation Garland Commercial IndustriesImportant Information Table of Contents Uncrating IntroductionUnits included in this manual are Rating PlateDimensions and Specifications Information Model Cu Ft Lbs/Kg Crated UncratedSalamander Performance and Construction InstallationGeneral Information National Code RequirementsInstallation Gas ConnectionsOptional Inter-Connect Kit Universal INTER-CONNECT KITRemove DetailModel UIR48 48 Ranges Detail For 48 Ranges With 2 Space Saver OvensClearance Hole Screws StepModel UIR60 60 Ranges With area detail defined for 60 inch rangeWall Or Counter Mounted Salamanders Model UIR36C Ventilation and Air Supply ClearancesOperation Daily Maintenance and CleaningExterior Cleaning MonthlyInstructions ’INSTALLATION ’UTILISATION ET D’ENTRETIEN Informations Importantes AvertissementDimensions ET Spécifications Informations Générales Table DES MatièresInformations Importantes Introduction Plaque Signalétique Appareils concernés par ce manuelDéballage Dimensions ET Spécifications DéballéInformations Générales Performance Et Construction Des SalamandresExigences Des Codes Nationaux Installation suite Connexions du gazKit D’interconnexion En Option Régulateur Fourni Avec LA SalamandreInstallation D’une Salamandre Sur Une Cuisinière Modèle UIR36 Cuisinières De 36 PoVIS DES Modèle UIR48 Cuisinières De 48 PoDétail Cuisinière DE 48 PO RetirerConvection ET Rangement Dégagement Trou DE Trous IntérieursDétail Toutes LES Cuisinières DE 48 PO VIS Parker FourniesModèle UIR60 Cuisinières De 60 Po Détail Tous LES Modèles DE 60 PO Cuisinière DE 60 PODétail Pour Cuisinière DE 60 PO Avec Four À Convection VIS Insérées Détail Tous LES Modèles DE 60 PODétail Pour Cuisinière DE 60 PO Avec Four Standard VIS TaraudeusesVentilation Et Alimentation En Air DégagementsUtilisation Chaque Mois Entretien ET NettoyageChaque Jour Nettoyage ExtérieurInstrucciones DE INSTALACIÓN, Operación Y Mantenimiento Información Importante AdvertenciaDimensiones Y Especificaciones Información General ÍndiceInformación Importante Introducción Desembalaje IntroducciónLas unidades incluidas en este manual son Placa De CaracterísticasDimensiones Y Especificaciones DesembaladoDesempeño Y Construcción De La Parrilla Salamandra Información GeneralInstalación Requisitos De Los Códigos NacionalesInstalación continuación Kit Opcional De Interconexión KIT Universal DE InterconexiónInstalación de una parrilla salamandra a una cocina Cocinas de 36- modelo UIR36Cocinas de 48- modelo UIR48 Quitar LOS TornillosTornillo Quitados AgujeroDetalle Para Todas LAS Cocinas DE Tornillo Para Hoja Metálicas ProporcionadosCocinas de 60- modelo UIR60 Para Cocinas DE 48 CON Hornos Ahorradores DE EspacioDE Paso Agujero Lados Detalle Todos LOS Modelos DEDE Ambos Detalle Para Cocinas DE CON Horno DE Convección ProvistosVentilación Y Suministro De Aire Instrucciones Para Encender Los Pilotos OperaciónSeparaciones Operación Del Quemador PrincipalInstrucciones De Apagado Período De QuemadoConservación De Energía Ajustes Al Quemador PrincipalMensualmente Mantenimiento Y LimpiezaDiariamente Limpieza ExteriorPágina Parte # 4523974 11/08/07 Página