Turbo Chef Technologies i5 service manual F7 RTD Open

Page 55

38 TROUBLESHOOTING

F7: RTD Open

This fault is displayed when the control detects that the RTD is “open.” The display will show a reading of “999ºF/C,” indicating the RTD is open.

The fault is cleared when the control detects continuity.

F8: Heat Low

This fault displays during WARMING UP or TEST MODE if the cook cavity temperature fails to rise at least 14ºF (7ºC) within a given 30 seconds.

Fault Code and Description

When Active

 

 

 

Refer to...

 

 

 

 

 

 

 

Warmup

Idle

Cooking

Test Mode

 

 

 

 

 

 

 

F1: Blower Running Status Bad

￿

￿

￿

￿

Page 39

 

 

 

 

 

 

F2: Cook Temperature Low

 

 

￿

 

Page 40

 

 

 

 

 

 

F3: Magnetron Current Low

 

 

￿

￿

Page 41

 

 

 

 

 

 

F4: Door Monitor Defective

 

 

￿

￿

Page 42

 

 

 

 

 

 

F5: Magnetron Over Temperature

 

 

￿

￿

Page 42

 

 

 

 

 

 

F6: EC Temperature High

￿

￿

￿

￿

Page 43

 

 

 

 

 

 

F7: RTD Open

￿

￿

￿

￿

Page 43

 

 

 

 

 

 

F8: Heat Low

￿

 

 

￿

Page 44

 

 

 

 

 

 

Figure 32: Fault Code Table

 

 

 

 

 

Fault codes are listed in order of hierarchy. For example, if during cooking the oven experiences an F1 and F2 fault, the oven will report only the F1 fault because the software will halt all actions upon discovering the F1 fault.

Fault codes F1 - F5 and F7 will terminate a cook cycle upon discovery.

Image 55
Contents Accelerating the World of Cooking TM Page For further information, call 800.90TURBO Page Table of Contents Oven Systems Edit ModeRTD Oven Schematic Appendix Replacing Oven Components TroubleshootingReducing Fire Risk General Safety InformationGrounding Instructions Power Cord ReplacementRF Interference Considerations Specifications and Installation Oven Construction DimensionsTheory of Operation CertificationsSingle Phase Electrical SpecificationsMulti Phase Lifting and Placing the Oven Unpacking InstructionsOptional Installation Items Installation Near Open Heat SourceVoltage Selection 32.0 813 mm This page intentionally Left blank Daily Maintenance Clean the Oven Interior Remove and Clean the Wire RackRemove and Clean the Lower Jetplate Remove and Clean the Lower Air DiverterClean the Oven Exterior Clean and Dry the Oven DoorReinstall Components Clean the Drain PanOven Controls and Cooking Oven Controls Cooking Mode 1 Oven OffMode 5 Ready to Cook or Idle Mode 2 Temperature SelectMode 3 Warming Up Mode 4 SoakMode 10 Cooling Down Mode 9 Cook MoreMode 7 Cooking Mode 8 Remove Food from OvenViewing Cook Counter/Time Logs Overview of the Info ModeViewing the Fault Log Viewing the Service NumbersInfo Mode Turning Oven Options On/Off Resetting the OvenSetting the Language Setting the Date/TimeTest Mode Turning On/Off Diagnostic Mode Test Mode Testing Oven PartsTest Mode Status Indicators Test Mode Fault LogMicrowave Leakage Test Test Mode Self TestTest Mode Manufacturing Mode Microwave Power TestSerial Number Edit Changing Temperature Measurement SettingErase/Default Oven Settings Loading a MenuInserting Smart Card/USB Device Updating the SoftwareEdit Mode Single vs. Multiple Temperature Mode Overview of the Edit ModeChanging Food Group/Recipe Name Changing Set TemperaturesChanging Recipe Settings This page intentionally Left blank Oven Systems Convection System Oven Door Troubleshooting Convection SystemRemoving/Reinstalling the Oven Door Adjusting the Oven DoorOven Systems Adjusting the Door Switches Interlock SwitchesHinges and Counter-Balance Assembly = Loosen = Tighten = Loosen Slightly Step Measuring RF Leakage for Microwave SafetySurvey Meter Placement TroubleshootingCapacitors Testing a CapacitorWiring the Filament Transformers Microwave SystemHigh-Voltage Diodes Wiring the High-Voltage TransformersTesting a Filament or HV Transformer High-Voltage TransformersTesting a High-Voltage Diode Magnetrons Testing a Magnetron for an Open/Shorted FilamentWave Guides Control System Relay K1 Filament Power SupplyHigh Limit Thermostat Magnetron ThermostatsSmart Card Reader Wire HarnessRelay K7 Magnetron Cooling Fan Relay K8 Stirrer Motor Air Filter Filtering System Catalytic Converter Drain PanTroubleshooting Fault Code Descriptions Overview of TroubleshootingF7 RTD Open Below Fault Code TroubleshootingNo YES Is the K6 mechanical Replace the F3 or F4 Are both cooling fans rotating? Yesno Non-Fault Code Troubleshooting Does the keypad beep when YES YES no Did you use a smart card or USB Smart Card Verify the USB device is Is the connection from Troubleshooting Oven Schematic Delta WYE This page intentionally Left blank Appendix Replacing Oven Components To Replace This First Remove This Comprehensive Table of Oven Components2APPENDIX Replacing Oven Components Replacing Items No Cover Removal Required Figures A-1, A-2 Figure A-1 No Cover Removal Required 16 174 5 11 12 13 15 16 Replacing Items Opening Top Cover Required Figure A-3Cover, Top I5-9243 Figure A-4 Removing Top Cover Required 13 14 15Figure A-6 Top Cover Detail Qty Figure A-7 Removing Left Side Cover Required Replacing Oven Components I5-9316 Screw, 10-32 x 3/8 lg, PFLH, 100 Deg, SS 101401 qty Oven Components For service or information
Related manuals