Turbo Chef Technologies Troubleshooting F3 Magnetron Current Low Error in TurboChef Ovens

Page 58

Troubleshooting:

F3: MAG CURR (Magnetron Current Low)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the K6 mechanical

Is control board

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

relay in good working

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U.S.

 

 

 

Intl.

 

 

 

Is the oven U.S. or International?

 

 

 

 

 

detecting 10A or

 

 

 

 

 

 

 

 

 

 

order?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

more current? Test

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for 24 VDC on pin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 of J7 connector

 

 

 

Replace the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(page 51).

 

 

 

 

 

 

control board.

 

 

Check the condition of the

 

 

 

 

 

 

 

 

 

Replace K6 relay

 

 

 

 

 

 

 

 

F3 and F4 fuses (pages 42,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See page A-8.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(see pages A-5

 

 

 

 

 

 

 

 

 

 

 

 

A-5 through A-6). Are they

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

through A-6).

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12-amps?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

Replace the F3

 

 

 

 

Is amperage present at the

 

NO

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

and/or F4 fuse (see

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current transformer even

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pages A-5 through

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

if the control board is not

 

 

Are the F3 and F4 fuses

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A-6) and verify the

 

 

 

 

detecting it?

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

functioning properly?

 

 

 

 

 

 

 

 

 

 

operation of the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

interlock switches

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(page 26).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

41

Run test cook cycles to see if fault repeats (page 10). If not, clear faults.

YES

Test the high-voltage transformers (page 30). Are the high voltage transformers functioning properly?

Test the high-voltage diodes (page 30). Are the diodes

functioning properly?

Did fault repeat?

Replace the capacitor(s). See page A-7 through A-8.

NO

YES

Replace the HV transformers(s). See page A-7 through A-8.

Test the filament transformers (page 30). Are the filament trans- formers functioning properly?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the filament

 

 

 

 

 

YES

 

 

 

transformers(s). See

 

 

 

 

 

 

 

 

 

 

page A-7 through A-8.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test the capacitors (page 29).

 

 

 

 

 

Are the capacitors

 

 

 

 

NO

 

 

 

 

 

 

 

 

functioning properly?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

diode(s). See page

 

 

 

 

 

 

 

 

 

 

A-7 through A-8.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test the magnetron for an

 

 

 

 

 

 

open/shorted filament (page

 

 

 

 

 

 

32). Are the filaments

 

 

 

 

 

 

functioning properly?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace the

 

Replace the

 

 

 

magnetron(s).

 

control board.

YES

 

 

 

See page A-12

 

See page A-8.

 

 

 

 

 

 

 

through A-13.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING

Image 58
Contents Accelerating the World of Cooking TM Page For further information, call 800.90TURBO Page Table of Contents Edit Mode Oven SystemsRTD Troubleshooting Oven Schematic Appendix Replacing Oven ComponentsGeneral Safety Information Reducing Fire RiskGrounding Instructions Power Cord ReplacementRF Interference Considerations Specifications and Installation Certifications DimensionsTheory of Operation Oven ConstructionSingle Phase Electrical SpecificationsMulti Phase Unpacking Instructions Lifting and Placing the OvenOptional Installation Items Installation Near Open Heat SourceVoltage Selection 32.0 813 mm This page intentionally Left blank Daily Maintenance Remove and Clean the Lower Air Diverter Remove and Clean the Wire RackRemove and Clean the Lower Jetplate Clean the Oven InteriorClean the Drain Pan Clean and Dry the Oven DoorReinstall Components Clean the Oven ExteriorOven Controls and Cooking Oven Controls Mode 1 Oven Off CookingMode 4 Soak Mode 2 Temperature SelectMode 3 Warming Up Mode 5 Ready to Cook or IdleMode 8 Remove Food from Oven Mode 9 Cook MoreMode 7 Cooking Mode 10 Cooling DownViewing the Service Numbers Overview of the Info ModeViewing the Fault Log Viewing Cook Counter/Time LogsInfo Mode Setting the Date/Time Resetting the OvenSetting the Language Turning Oven Options On/OffTest Mode Fault Log Test Mode Testing Oven PartsTest Mode Status Indicators Test Mode Turning On/Off Diagnostic ModeMicrowave Power Test Test Mode Self TestTest Mode Manufacturing Mode Microwave Leakage TestLoading a Menu Changing Temperature Measurement SettingErase/Default Oven Settings Serial Number EditUpdating the Software Inserting Smart Card/USB DeviceEdit Mode Overview of the Edit Mode Single vs. Multiple Temperature ModeChanging Set Temperatures Changing Food Group/Recipe NameChanging Recipe Settings This page intentionally Left blank Oven Systems Convection System Adjusting the Oven Door Troubleshooting Convection SystemRemoving/Reinstalling the Oven Door Oven DoorOven Systems Adjusting the Door Switches Interlock SwitchesHinges and Counter-Balance Assembly Measuring RF Leakage for Microwave Safety = Loosen = Tighten = Loosen Slightly StepTroubleshooting Survey Meter PlacementMicrowave System Testing a CapacitorWiring the Filament Transformers CapacitorsHigh-Voltage Transformers Wiring the High-Voltage TransformersTesting a Filament or HV Transformer High-Voltage DiodesTesting a High-Voltage Diode Magnetrons Testing a Magnetron for an Open/Shorted FilamentWave Guides Control System Magnetron Thermostats Power SupplyHigh Limit Thermostat Relay K1 FilamentRelay K8 Stirrer Motor Wire HarnessRelay K7 Magnetron Cooling Fan Smart Card ReaderDrain Pan Filtering SystemCatalytic Converter Air FilterTroubleshooting Overview of Troubleshooting Fault Code Descriptions F7 RTD Open Fault Code Troubleshooting BelowNo YES Is the K6 mechanical Replace the F3 or F4 Are both cooling fans rotating? Yesno Non-Fault Code Troubleshooting Does the keypad beep when YES YES no Did you use a smart card or USB Smart Card Verify the USB device is Is the connection from Troubleshooting Oven Schematic Delta WYE This page intentionally Left blank Appendix Replacing Oven Components Comprehensive Table of Oven Components To Replace This First Remove This2APPENDIX Replacing Oven Components Replacing Items No Cover Removal Required Figures A-1, A-2 16 17 Figure A-1 No Cover Removal RequiredReplacing Items Opening Top Cover Required Figure A-3 4 5 11 12 13 15 16Cover, Top I5-9243 13 14 15 Figure A-4 Removing Top Cover RequiredFigure A-6 Top Cover Detail Qty Figure A-7 Removing Left Side Cover Required Replacing Oven Components I5-9316 Screw, 10-32 x 3/8 lg, PFLH, 100 Deg, SS 101401 qty Oven Components For service or information
Related manuals
Manual 34 pages 18.03 Kb