Turbo Chef Technologies i5 Test Mode Testing Oven Parts, Test Mode Status Indicators

Page 29

Test Mode - Testing Oven Parts

From screen 2 of the Info mode, press the L1 soft key to access TEST MODE. When prompted, enter the password 9 4 2 8 and press the Enter key.

From TEST MODE, the oven’s components can be tested independently, or a comprehensive/ selective self-test can be run. Unless otherwise specified, idle airflow is set to 10% and the stirrer motor is turned on.

Top Blower

Press the L2 soft key to increase top blower speed in 10% increments.

NOTE: While the top blower is being tested, the bottom blower remains at 10% idle airflow.

Bottom Blower

Press the L3 soft key to increase bottom blower speed in 10% increments.

NOTE: While bottom blower is being tested, the top blower remains at 10% idle airflow.

Heaters

Press the L4 soft key to turn heaters on/off.

NOTE: When the heaters are not being tested, make sure they are turned off; otherwise, the oven will overheat.

Magnetron Test

Press and hold the L5 soft key to turn on the magnetrons. To turn off the magnetrons, simply let go of the L5 soft key.

Stirrer

Press the R1 soft key to turn the stirrer on/off.

L1

TEST MODE

R1

 

 

 

FAULT LOG

 

 

 

 

STIRRER ON

 

L2

TOP BLOWER 10%

 

 

 

 

DIAGNOSTICS OFF

R2

L3

BOTTOM BLOWER 20%

MANUFACTURING MODE

R3

 

 

L4

HEATERS ON

 

 

 

 

SELF TEST

R4

 

 

 

 

 

 

L5

MAG OFF

 

 

 

 

 

R5

P S M t

H

 

B

T

W

Figure 14: Test Mode

15

Test Mode - Status Indicators

Figure 14. The status indicators are located at the bottom of the TEST MODE screen, and consist of:

-P = Primary switch (backlit = open)

-S = Secondary switch (backlit = open)

-M = Monitor switch (backlit = open)

-t = Magnetron thermostat (backlit = open)

-H = Heaters (backlit = on)

-B = Bottom blower (backlit = on)

-T = Top blower (backlit = on)

-W = Microwave (backlit = on)

In Figure 14:

-All three door switches are engaged (closed).

-The heaters are on.

-Both blower motors are on.

-Microwave is not being used.

Test Mode - Fault Log

Press the L1 soft key to access the fault log.

This fault log is identical to the one accessible from screen 1 of the INFO MODE (page 13), except on this screen, pressing the 0 key clears all faults.

Test Mode - Turning On/Off

Diagnostic Mode

Press the R2 soft key to place the oven in

DIAGNOSTIC MODE. When in DIAGNOSTIC MODE,

the oven displays additional cooking parameters during a cook cycle, including:

-Event currently being cooked

-Time left per event

-% wave, % top air, % bottom air

-Status indicators

-Group and recipe name

-CC temperature

-CC set point

For normal oven operation, ensure DIAGNOSTIC MODE is turned off.

INFO MODE

Image 29
Contents Accelerating the World of Cooking TM Page For further information, call 800.90TURBO Page Table of Contents Oven Systems Edit ModeRTD Oven Schematic Appendix Replacing Oven Components TroubleshootingReducing Fire Risk General Safety InformationRF Interference Considerations Power Cord ReplacementGrounding Instructions Specifications and Installation Theory of Operation DimensionsCertifications Oven ConstructionMulti Phase Electrical SpecificationsSingle Phase Lifting and Placing the Oven Unpacking InstructionsVoltage Selection Installation Near Open Heat SourceOptional Installation Items 32.0 813 mm This page intentionally Left blank Daily Maintenance Remove and Clean the Lower Jetplate Remove and Clean the Wire RackRemove and Clean the Lower Air Diverter Clean the Oven InteriorReinstall Components Clean and Dry the Oven DoorClean the Drain Pan Clean the Oven ExteriorOven Controls and Cooking Oven Controls Cooking Mode 1 Oven OffMode 3 Warming Up Mode 2 Temperature SelectMode 4 Soak Mode 5 Ready to Cook or IdleMode 7 Cooking Mode 9 Cook MoreMode 8 Remove Food from Oven Mode 10 Cooling Down Viewing the Fault Log Overview of the Info Mode Viewing the Service Numbers Viewing Cook Counter/Time LogsInfo Mode Setting the Language Resetting the OvenSetting the Date/Time Turning Oven Options On/OffTest Mode Status Indicators Test Mode Testing Oven PartsTest Mode Fault Log Test Mode Turning On/Off Diagnostic ModeTest Mode Manufacturing Mode Test Mode Self TestMicrowave Power Test Microwave Leakage TestErase/Default Oven Settings Changing Temperature Measurement SettingLoading a Menu Serial Number EditInserting Smart Card/USB Device Updating the SoftwareEdit Mode Single vs. Multiple Temperature Mode Overview of the Edit ModeChanging Food Group/Recipe Name Changing Set TemperaturesChanging Recipe Settings This page intentionally Left blank Oven Systems Convection System Removing/Reinstalling the Oven Door Troubleshooting Convection SystemAdjusting the Oven Door Oven DoorOven Systems Hinges and Counter-Balance Assembly Interlock SwitchesAdjusting the Door Switches = Loosen = Tighten = Loosen Slightly Step Measuring RF Leakage for Microwave SafetySurvey Meter Placement TroubleshootingWiring the Filament Transformers Testing a CapacitorMicrowave System CapacitorsTesting a Filament or HV Transformer Wiring the High-Voltage TransformersHigh-Voltage Transformers High-Voltage DiodesTesting a High-Voltage Diode Wave Guides Testing a Magnetron for an Open/Shorted FilamentMagnetrons Control System High Limit Thermostat Power SupplyMagnetron Thermostats Relay K1 FilamentRelay K7 Magnetron Cooling Fan Wire HarnessRelay K8 Stirrer Motor Smart Card ReaderCatalytic Converter Filtering SystemDrain Pan Air FilterTroubleshooting Fault Code Descriptions Overview of TroubleshootingF7 RTD Open Below Fault Code TroubleshootingNo YES Is the K6 mechanical Replace the F3 or F4 Are both cooling fans rotating? Yesno Non-Fault Code Troubleshooting Does the keypad beep when YES YES no Did you use a smart card or USB Smart Card Verify the USB device is Is the connection from Troubleshooting Oven Schematic Delta WYE This page intentionally Left blank Appendix Replacing Oven Components To Replace This First Remove This Comprehensive Table of Oven Components2APPENDIX Replacing Oven Components Replacing Items No Cover Removal Required Figures A-1, A-2 Figure A-1 No Cover Removal Required 16 174 5 11 12 13 15 16 Replacing Items Opening Top Cover Required Figure A-3Cover, Top I5-9243 Figure A-4 Removing Top Cover Required 13 14 15Figure A-6 Top Cover Detail Qty Figure A-7 Removing Left Side Cover Required Replacing Oven Components I5-9316 Screw, 10-32 x 3/8 lg, PFLH, 100 Deg, SS 101401 qty Oven Components For service or information