Toshiba VF-S11 manual Ry Rc

Page 17

 

 

 

 

 

E6581160

 

 

 

 

 

 

 

 

Terminal

Input/output

Function

Electrical

Inverter internal circuits

 

symbol

specifications

 

 

 

 

 

2

RY RC

Output

Multifunction programmable relay contact output.

Standard default settings detect and output low-speed signal output frequencies.

Multifunction output terminals to which two different functions can be assigned.

250Vac-1A (cosφ=1)

:at resistance load 30Vdc-0.5A 250Vac-0.5A (cosφ=0.4)

+24V

RY RY RC

QSINK (Negative) logic/SOURCE (Positive) logic (When the

inverter's internal power supply is used)

Current flowing out turns control input terminals on. These are called sink logic terminals. (Type: -AN/-WN). The general used method in Europe is source logic in which current flowing into the input terminal turns it on (Typ: -WP).

Sink logic is sometimes referred to as negative logic, and source logic is referred to as positive logic. Each logic is supplied with electricity from either the inverter's internal power supply or an external power supply, and its connections vary depending on the power supply used.

Examples of connections when the inverter's internal power supply is used

Slide switch SW1:SINK

Slide switch SW1:SOURCE

 

 

 

 

 

Sink (Negative) logic

 

 

Source (Positive) logic

 

 

 

 

 

 

 

24VDC

Input

 

 

Output

F

 

Common

CC

 

 

24VD

Output

Common

P24

 

Input

OUT

 

 

NO

 

 

CC

 

 

24VDC

 

Common

P24

Input

 

Output

F

 

 

24VDC

Output

 

 

 

P24

 

 

OUT

 

Input

NO

 

Common CC

 

Programmable

Inverter

Programmable

Inverter

controller

 

controller

 

16

Image 17
Contents Industrial Inverter For 3-phase induction motorsMeanings of symbols Safety precautionsSafety precautions Explanation of markingsGeneral Operation Wiring Transportation & installationOperations Maintenance and inspection When retry function is selected inverter Contents  Check product purchase Read firstCD-ROM E6581167 Installation Contents of the productConnection Standard connection diagramStandard connections VF-S11FLB FLCFLA PLC OUTSelection of wiring materials Power circuit terminalsPower circuit Description of terminals Control circuit terminals SW1 Control circuit terminals24VDC PLC VIAFLB FLA PTCRY RC Slide switch SW1PLC Source Positive logic SW1 Source PLC Sink Simplified Operation of the VF-S11 OperationsEoqf HoqfStart and stop using the operation panel keys EOQF= How to start and stopCoast stop Example of operating a run from the panel How to set the frequencyHOQF= Frequency setting Setting the frequency using the operation panel HOQF= or Running and stopping using the operation panel How to operate the VF-S11Ex.2 Ex.3 Running and stopping using external signalsVIA Basic VF-S11 operations Status monitor mode Mode for monitoring all inverter statusPanel jog mode Past trip record detained monitor mode Flow of status monitor modeStandard monitor mode Parameters for detailed and special setting. See How to set parametersWhen you adjust the inverter repeatedly using Same parameter. Parameter name CWJ. See⇔HJ How to set the basic parameters ~H How to set extended parameters How to search and reprogram parameters Search and resetting of changed parameters I4WExample of parameter setting  ⇔ CEE  ⇔CEE How to use the history functionParameters that cannot be changed while running Kpkv Returning all parameters to standard default settingHow to save/load the user setting parameters Status monitor under normal conditions Status monitor modeMonitoring the operation status Iiii  Pgtt ⇔Display of detailed information on a past trip Trip code display Display of trip informationDisplay of trip information at the occurrence of a trip Example of call-up of trip informationQR ⇔ OFF VIA VIB RESCumulative E6581160 About the EMC directive How to cope with the CE directiveMeasures to satisfy the standards Measures to satisfy the EMC directive Three-phase 500V class About the low-voltage directive Example of wiringCompliance with UL Standard and CSA Standard Compliance with InstallationMeasures to satisfy the low-voltage directive Compliance with ConnectionMotor thermal protection AIC, Fuse and Wire sizesAIC a AWGUser parameters Table of parameters and dataBasic parameters Four navigation functionsCEE  QNOInput/output parameters Extended parametersFrequency parameters   Operation mode parameters   Torque boost parameters Protection parameters Acceleration/deceleration time parameters  Operation panel parameters Output parametersCommunication parameters PM motor parameters XD/H        Default settings by inverter ratingAD2 Table of input terminal functions, H, H, H +SS3+AD2AD3 Table of output terminal functionsQN-,QNT ,QJ,WR,GH,WE,On QE-,QR-,QJ, Fcvibn Standard specifications SpecificationsModels and their standard specifications Characteristics Common specificationSpecification Outside dimensions and mass Outside dimensions and massVF-S11 Outline drawingFig.D Trip causes/warnings and remedies Before making a service call Trip information and remediesQNT   Industrial and Power Systems & Services Company