E6581160
QTable of output terminal functions 2
|
| Function | Code | Function | Action | |
|
| No. | ||||
|
|
|
|
| ||
|
| 12 | OT | ON: Torque current is equal to or larger than | ||
|
|
|
|
| H set value and longer than H | |
|
|
|
|
| set time. | |
|
|
|
|
| OFF: The torque current is equal to or less than | |
|
|
|
|
| (H set value - H set value). | |
|
| 13 | OTN | Inversion of | Inversion of OT | |
|
| 14 | RUN | Start/Stop | ON: When operation frequency is output or during | |
|
|
|
|
| (FD) | |
|
|
|
|
| OFF: Operation stopped | |
|
| 15 | RUNN | Inversion of RUN/STOP | Inversion of RUN setting | |
|
| 16 | POL | OL | ON: 50% or more of calculated value of overload | |
|
|
|
|
| protection level | |
|
|
|
|
| OFF: Less than 50% of calculated value of | |
|
|
|
|
| overload protection level | |
|
| 17 | POLN | Inversion of OL | Inversion of POL setting | |
|
| 18 | POHR | Braking resistor overload | ON: 50% or more of calculated value of H | |
|
|
|
|
| set overload protection level | |
|
|
|
|
| OFF: Less than 50% of calculated value of | |
|
|
|
|
| H set overload protection level | |
|
| 19 | POHRN | Inversion of braking resistor overload | Inversion of RCHR setting | |
|
| 20 | POT | ON: Torque current is equal to or larger than 70% | ||
|
|
|
|
| of H set value. | |
|
|
|
|
| OFF: The torque current is below (H set | |
|
|
|
|
| value x 70% - H set value). | |
|
| 21 | POTN | Inversion of | Inversion of POT setting | |
7 | ||||||
| 22 | PAL | One of the following is turned on: | |||
|
|
|
| ON POL, POHR, POT, MOFF, UC, OT, LL | ||
|
|
|
| stop, COT, and momentary power failure | ||
|
|
|
|
| slowdown stop. | |
|
|
|
|
| or E,R,QTJ issues an alarm | |
|
|
|
|
| All the following are turned off: | |
|
|
|
|
| OFF POL, POHR, POT, MOFF, UC, OT, LL | |
|
|
|
|
| stop, COT, and momentary power failure | |
|
|
|
|
| slowdown stop. | |
|
|
|
|
| or E,R,QTJ issues no alarm | |
|
| 23 | PALN | Inversion of | Inversion of PAL setting | |
|
| 24 | UC | ON: The output current is equal to or less than | ||
|
|
|
|
| H set value for H set time. | |
|
|
|
|
| OFF: The output current is equal to or larger than | |
|
|
|
|
| H set value + 10%. | |
|
| 25 | UCN | Inversion of | Inversion of UC setting | |
|
| 26 | HFL | Significant failure | ON: QEC,QEN,QV,G, | |
|
|
|
|
| GGR,GVP,GRJQ,GTT- | |
|
|
|
|
| ,QJ,WR,GH,WE, | |
|
|
|
|
| GV[R,QTGRJ) | |
|
|
|
|
| OFF: Failure other than the above | |
|
| 27 | HFLN | Inversion of significant failure | Inversion of HFL setting | |
|
| 28 | LFL | Insignificant failure | ON: | |
|
|
|
|
|
| |
|
|
|
|
| OFF: Failure other than the above | |
|
| 29 | LFLN | Inversion of insignificant failure | Inversion of LFL setting | |
|
| 30 | RDY1 | Ready for operation (including ST/RUN) | ON: Ready for operation (ST and RUN are also | |
|
|
|
|
| ON) | |
|
|
|
|
| OFF: Others | |
|
| 31 | RDY1N | Inversion of ready for operation (including | Inversion of RDY1 setting | |
|
|
|
| ST/RUN) |
| |
|
| 32 | RDY2 | Ready for operation (excluding ST/RUN) | ON: Ready for operation (ST and RUN are not | |
|
|
|
|
| ON) | |
|
|
|
|
| OFF: Others | |
|
| 33 | RDY2N | Inversion of ready for operation (excluding ST/RUN) | Inversion of RDY2 | |
|
| 34 | FCVIB | Frequency VIB selection | ON: VIB selected as frequency command | |
|
|
|
|
| OFF: Terminal other than VIB selected as | |
|
|
|
|
| frequency command |
68