5. Monitoring the operation status

Refer to 4.1 about flow of monitor.

5.1Status monitor mode

5.1.1Status monitor under normal conditions

In this mode, you can monitor the operation status of the inverter.

To display the operation status during normal operation:

Press the MODE key twice.

Setting procedure (eg. operation at 60Hz)

 

 

 

 

 

Item displayed

 

Key

LED

Communic

Description

5

 

 

 

 

operated

display

ation No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.

 

The operation frequency is displayed (Operation at

 

 

 

 

 

 

 

 

 

 

60Hz). (When standard monitor display selection

 

 

 

 

 

 

 

 

 

 

 

H is set at 0 [operation frequency])

 

 

 

 

 

Parameter setting

 

MODE

CWJ

 

The first basic parameter “CWJ” (history function)

 

 

 

 

 

mode

 

 

is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Direction of

 

MODE

HTH

FE01

The direction of rotation is displayed.

 

 

 

 

 

rotation

 

(HTH: forward run, HTT: reverse run)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

 

 

 

 

The operation frequency command value (Hz/free

 

 

 

 

 

 

 

 

 

 

 

 

Note 1

 

 

 

 

 

 

 

 

 

frequency

 

 

 

H

FE02

unit) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

command

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The inverter output current (load current) (%/A) is

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 2

 

Load current

 

 

 

E

FE03

 

 

 

 

 

 

displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input voltage

 

 

 

 

FE04

The inverter input (DC) voltage (%/V) is displayed.

 

 

Note 3

 

 

 

[

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output voltage

 

 

 

R

FE05

The inverter output voltage (%/V) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Torque

 

 

 

SQ

FE18

The torque (%) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Torque current

 

 

 

Y

FE20

The torque current (%/A) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inverter load factor

 

 

 

N

FE27

The inverter load factor (%) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PBR cumulative

 

 

 

T

FE25

The cumulative load factor of the braking resistor

 

 

 

 

 

load factor

 

 

 

(%) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input power

 

 

 

k

FE29

The inverter input power (kW) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output power

 

 

 

J

FE30

The inverter output power (kW) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation

 

 

 

Z

FD00

The operation frequency (Hz/free unit) is

 

 

 

 

 

frequency

 

 

 

displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Continued overleaf)

36

Image 37
Contents Industrial Inverter For 3-phase induction motorsMeanings of symbols Safety precautionsSafety precautions Explanation of markingsGeneral Operation Wiring Transportation & installationOperations Maintenance and inspection When retry function is selected inverter Contents  Check product purchase Read firstCD-ROM E6581167 Installation Contents of the productConnection Standard connection diagramStandard connections VF-S11FLB FLCFLA PLC OUTSelection of wiring materials Power circuit terminalsPower circuit Description of terminalsControl circuit terminals SW1 Control circuit terminals24VDC PLC VIAFLB FLA PTCRY RC Slide switch SW1PLC Source Positive logic SW1 Source PLC Sink Simplified Operation of the VF-S11 OperationsEoqf HoqfStart and stop using the operation panel keys EOQF= How to start and stopCoast stop HOQF= How to set the frequencyExample of operating a run from the panel Frequency setting Setting the frequency using the operation panel HOQF= or Running and stopping using the operation panel How to operate the VF-S11Ex.2 Ex.3 Running and stopping using external signalsVIA Panel jog mode Status monitor mode Mode for monitoring all inverter statusBasic VF-S11 operations Standard monitor mode Flow of status monitor modePast trip record detained monitor mode Parameters for detailed and special setting. See How to set parametersWhen you adjust the inverter repeatedly using Same parameter. Parameter name CWJ. See How to set the basic parameters⇔HJ  How to set extended parameters~H Example of parameter setting Search and resetting of changed parameters I4WHow to search and reprogram parameters   ⇔ CEE Parameters that cannot be changed while running How to use the history function⇔CEE How to save/load the user setting parameters Returning all parameters to standard default settingKpkv Monitoring the operation status Status monitor modeStatus monitor under normal conditions Iiii  Pgtt ⇔Display of detailed information on a past trip Trip code display Display of trip informationDisplay of trip information at the occurrence of a trip Example of call-up of trip informationQR ⇔ OFF VIA VIB RESCumulative E6581160 Measures to satisfy the standards How to cope with the CE directiveAbout the EMC directive Measures to satisfy the EMC directive Three-phase 500V class About the low-voltage directive Example of wiringCompliance with UL Standard and CSA Standard Compliance with InstallationMeasures to satisfy the low-voltage directive Compliance with ConnectionMotor thermal protection AIC, Fuse and Wire sizesAIC a AWGUser parameters Table of parameters and dataBasic parameters Four navigation functionsCEE  QNOInput/output parameters Extended parametersFrequency parameters   Operation mode parameters   Torque boost parameters Protection parameters Acceleration/deceleration time parameters  Operation panel parameters Output parametersCommunication parameters PM motor parameters XD/H        Default settings by inverter ratingAD2 Table of input terminal functions, H, H, H +SS3+AD2AD3 Table of output terminal functionsOn QE-,QR-,QJ, ,QJ,WR,GH,WE,QN-,QNT Fcvibn Models and their standard specifications SpecificationsStandard specifications Characteristics Common specificationSpecification Outside dimensions and mass Outside dimensions and massVF-S11 Outline drawingFig.D Trip causes/warnings and remedies Before making a service call Trip information and remediesQNT   Industrial and Power Systems & Services Company