Toshiba VF-S11 manual Before making a service call Trip information and remedies

Page 77

E6581160

9.Before making a service call

- Trip information and remedies

9.1Trip causes/warnings and remedies

When a problem arises, diagnose it in accordance with the following table.

If it is found that replacement of parts is required or the problem cannot be solved by any remedy described in the table, contact your Toshiba dealer.

[Trip information]

 

 

Error code

Failure code

Problem

Possible causes

Remedies

 

 

QE

0001

Overcurrent during

The acceleration time CEE is too short.

Increase the acceleration time CEE.

 

 

QER

0025

acceleration

The V/F setting is improper.

Check the V/F parameter.

 

 

 

 

Overcurrent flowing

A restart signal is imput to the rotating

Use H (auto-restart) and H

 

 

 

 

in element during

motor after a momentary stop, etc.

(ride-through control).

 

 

 

 

acceleration

A special motor (e.g. motor with a small

Adjust the carrier frequency H.

 

 

 

 

 

impedance) is used.

Set the carrier frequency control mode

 

 

 

 

 

 

selection parameter f316 to 1 or 3

 

 

 

 

 

 

(carrier frequency decreased

 

 

 

 

 

 

automatically).

 

 

QE

0002

Overcurrent during

The deceleration time FGE is too short.

Increase the deceleration time FGE.

 

 

QER

0026

deceleration

 

Set the carrier frequency control mode

 

 

 

 

Overcurrent flowing

 

selection parameter f316 to 1 or 3

 

 

 

 

in element during

 

(carrier frequency decreased

 

 

 

 

decelearion

 

automatically).

 

 

QE

0003

Overcurrent during

The load fluctuates abruptly.

Reduce the load fluctuation.

9

 

QER

0027

constant speed

The load is in an abnormal condition.

Check the load (operated machine).

 

 

 

operation

 

Set the carrier frequency control mode

 

 

 

Overcurrent flowing

 

selection parameter f316 to 1 or 3

 

 

 

 

in element during

 

(carrier frequency decreased

 

 

 

 

operation

 

automatically).

 

 

ER

0025

Ground fault trip

A current leaked from an output cable or

Check cables, connectors, and so on for

 

 

ER

0026

Arm overcurrent at

the motor to ground.

ground faults.

 

 

0027

start-up

A main circuit elements is defective.

Make a service call.

 

 

ER

 

(for 11 and 15 kW

 

 

 

 

 

 

models only)

 

 

 

 

QEN

0004

Overcurrent (An

The insulation of the output main circuit or

Check the cables and wires for defective

 

 

 

 

overcurrent on the

motor is defective.

insulation.

 

 

 

 

load side at start-up)

The motor has too small impedance.

When using a 11 or 15 kW model, check

 

 

 

 

 

A 11 or 15 kW model was started,

cables, connectors, and so on for ground

 

 

 

 

 

although a current is leaked from an

faults.

 

 

 

 

 

output cable or the motor to ground.

 

 

 

QEC

0005

Arm overcurrent at

A main circuit elements is defective.

Make a service call.

 

 

 

 

start-up

 

 

 

 

*

0008

Input phase failure

A phase failure occured in the input line of

Check the main circuit input line for phase

 

 

GRJ

 

 

the main circuit.

failure.

 

 

 

 

The capacitor in the main circuit lacks

Enable H (input phase failure

 

 

 

 

 

 

 

 

 

 

capacitance.

detection).

 

 

 

 

 

 

Check the capacitor in the main circuit for

 

 

 

 

 

 

exhaustion.

 

 

*

0009

Output phase failure

A phase failure occurred in the output line

Check the main circuit output line, motor,

 

 

GRJQ

 

 

of the main circuit.

etc. for phase failure.

 

 

 

 

 

Enable H (Output phase failure

 

 

 

 

 

 

 

 

 

 

 

 

detection).

*You can select a trip ON/OFF by parameters. (Continued overleaf)

76

Image 77
Contents Industrial Inverter For 3-phase induction motorsMeanings of symbols Safety precautionsSafety precautions Explanation of markingsGeneral Operation Wiring Transportation & installationOperations Maintenance and inspection When retry function is selected inverter Contents  Check product purchase Read firstCD-ROM E6581167 Installation Contents of the productConnection Standard connection diagramStandard connections VF-S11FLB FLCFLA PLC OUTSelection of wiring materials Power circuit terminalsPower circuit Description of terminalsControl circuit terminals SW1 Control circuit terminals24VDC PLC VIAFLB FLA PTCRY RC Slide switch SW1PLC Source Positive logic SW1 Source PLC Sink Simplified Operation of the VF-S11 OperationsEoqf HoqfStart and stop using the operation panel keys EOQF= How to start and stopCoast stop Example of operating a run from the panel How to set the frequencyHOQF= Frequency setting Setting the frequency using the operation panel HOQF= or Running and stopping using the operation panel How to operate the VF-S11Ex.2 Ex.3 Running and stopping using external signalsVIA Basic VF-S11 operations Status monitor mode Mode for monitoring all inverter statusPanel jog mode Past trip record detained monitor mode Flow of status monitor modeStandard monitor mode Parameters for detailed and special setting. See How to set parametersWhen you adjust the inverter repeatedly using Same parameter. Parameter name CWJ. See⇔HJ How to set the basic parameters ~H How to set extended parameters How to search and reprogram parameters Search and resetting of changed parameters I4WExample of parameter setting  ⇔ CEE  ⇔CEE How to use the history functionParameters that cannot be changed while running Kpkv Returning all parameters to standard default settingHow to save/load the user setting parameters Status monitor under normal conditions Status monitor modeMonitoring the operation status Iiii  Pgtt ⇔Display of detailed information on a past trip Trip code display Display of trip informationDisplay of trip information at the occurrence of a trip Example of call-up of trip informationQR ⇔ OFF VIA VIB RESCumulative E6581160 About the EMC directive How to cope with the CE directiveMeasures to satisfy the standards Measures to satisfy the EMC directive Three-phase 500V class About the low-voltage directive Example of wiringCompliance with UL Standard and CSA Standard Compliance with InstallationMeasures to satisfy the low-voltage directive Compliance with ConnectionMotor thermal protection AIC, Fuse and Wire sizesAIC a AWGUser parameters Table of parameters and dataBasic parameters Four navigation functionsCEE  QNOInput/output parameters Extended parametersFrequency parameters   Operation mode parameters   Torque boost parameters Protection parameters Acceleration/deceleration time parameters  Operation panel parameters Output parametersCommunication parameters PM motor parameters XD/H        Default settings by inverter ratingAD2 Table of input terminal functions, H, H, H +SS3+AD2AD3 Table of output terminal functionsQN-,QNT ,QJ,WR,GH,WE,On QE-,QR-,QJ, Fcvibn Standard specifications SpecificationsModels and their standard specifications Characteristics Common specificationSpecification Outside dimensions and mass Outside dimensions and massVF-S11 Outline drawingFig.D Trip causes/warnings and remedies Before making a service call Trip information and remediesQNT   Industrial and Power Systems & Services Company