Toshiba VF-S11 manual Acceleration/deceleration time parameters, Protection parameters

Page 60

E6581160

Acceleration/deceleration time parameters

 

Communication

 

 

Minimum

 

 

 

 

 

 

Title

Function

Unit

setting unit

Adjustment range

Default

User

Reference

 

No.

Panel/Commun

setting

setting

E6581158

 

 

 

 

 

 

 

 

 

 

 

ication

 

 

 

 

 

 

H

0500

Acceleration time

s

0.1/0.1

0.0-3200

10.0

 

6.18

 

 

 

 

2

 

 

 

 

 

 

 

 

H

0501

Deceleration time

s

0.1/0.1

0.0-3200

10.0

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

H

0502

Acceleration/decel

-

-

0: Linear

0

 

 

 

 

 

 

eration 1 pattern

 

 

1: S-pattern 1

 

 

 

 

 

H

0503

Acceleration/decel

-

-

2: S-pattern 2

0

 

 

 

 

 

 

eration 2 pattern

 

 

 

 

 

 

 

 

H

0504

Acceleration/decel

-

-

1: Acceleration/deceleration 1

1

 

 

 

 

 

 

eration selection

 

 

2: Acceleration/deceleration 2

 

 

 

 

 

 

 

(1, 2 , 3)

 

 

3: Acceleration/deceleration 3

 

 

 

 

 

H

0505

Acceleration/decel

Hz

0.1/0.01

0.0-WN

0.0

 

 

 

 

 

 

eration 1 and 2

 

 

 

 

 

 

 

 

 

 

switching

 

 

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

H

0506

S-pattern lower-

%

1/1

0-50

10

 

 

 

 

 

 

limit adjustment

 

 

 

 

 

 

 

 

 

 

amount

 

 

 

 

 

 

 

 

H

0507

S-pattern upper-

%

1/1

0-50

10

 

6.18

 

 

 

 

limit adjustment

 

 

 

 

 

 

 

 

 

 

amount

 

 

 

 

 

 

 

 

H

0510

Acceleration time

s

0.1/0.1

0.0-3200

10.0

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

H

0511

Deceleration time

s

0.1/0.1

0.0-3200

10.0

 

 

 

 

 

3

 

 

 

 

 

 

 

 

H

0512

Acceleration/decel

-

-

0: Linear

0

 

 

 

 

 

 

 

 

 

 

eration 3 pattern

 

 

1: S-pattern 1

 

 

 

 

 

 

 

 

 

 

2: S-pattern 2

 

 

 

 

 

H

0513

Acceleration/decel

Hz

0.1/0.01

0.0-WN

0.0

 

 

 

 

 

 

eration 2 and 3

 

 

 

 

 

 

 

 

 

 

switching

 

 

 

 

 

 

 

 

 

 

frequency

 

 

 

 

 

 

 

 

Protection parameters

 

Communication

 

 

Minimum

 

 

 

 

Title

Function

Unit

setting unit

Adjustment range

Default

User

Reference

No.

Panel/Commun

setting

setting

E6581158

 

 

 

 

 

 

 

 

ication

 

 

 

 

H

0601

Stall prevention

%

1/1

10-199

150

 

6.19.2

 

 

level 1

(A)

 

200 (disabled)

 

 

 

H

0602

Inverter trip

-

-

0: Canceled with the power off

0

 

6.19.3

 

 

retention selection

 

 

1: Still retained with the power off

 

 

 

H

0603

Emergency stop

-

-

0: Coast stop

0

 

6.19.4

 

 

selection

 

 

1: Slowdown stop

 

 

 

 

 

 

 

 

2: Emergency DC braking

 

 

 

H

0604

Emergency DC

s

0.1/0.1

0.0-20.0

1.0

 

6.19.4

 

 

braking time

 

 

 

 

 

 

H

0605

Output phase

-

-

0: Disabled

0

 

6.19.5

 

 

failure detection

 

 

1: At start-up (only one time after

 

 

 

 

 

mode selection

 

 

power is turned on)

 

 

 

 

 

 

 

 

2: At start-up (each time)

 

 

 

 

 

 

 

 

3: During operation

 

 

 

 

 

 

 

 

4: At start-up + during operation

 

 

 

 

 

 

 

 

5: Detection of cutoff on output side

 

 

 

H

0607

Motor 150%-

s

1/1

10-2400

300

 

6.19.1

 

 

overload time limit

 

 

 

 

 

 

H

0608

Input phase failure

-

-

0: Disabled, 1: Enabled

1

 

6.19.6

 

 

detection mode

 

 

 

 

 

 

 

 

selection

 

 

 

 

 

 

59

Image 60
Contents For 3-phase induction motors Industrial InverterSafety precautions Meanings of symbolsSafety precautions Explanation of markingsGeneral Operation Transportation & installation WiringOperations When retry function is selected inverter Maintenance and inspection Contents  Read first Check product purchaseCD-ROM E6581167 Contents of the product InstallationStandard connection diagram ConnectionStandard connections VF-S11FLC FLBFLA PLC OUTPower circuit terminals Selection of wiring materialsPower circuit Description of terminalsControl circuit terminals Control circuit terminals SW124VDC PLC VIAPTC FLB FLARY RC Slide switch SW1PLC Source Positive logic SW1 Source PLC Sink Operations Simplified Operation of the VF-S11Eoqf HoqfHow to start and stop Start and stop using the operation panel keys EOQF=Coast stop How to set the frequency HOQF=Example of operating a run from the panel Setting the frequency using the operation panel HOQF= or  Frequency settingHow to operate the VF-S11 Running and stopping using the operation panelEx.2 Running and stopping using external signals Ex.3VIA Status monitor mode Mode for monitoring all inverter status Panel jog modeBasic VF-S11 operations Flow of status monitor mode Standard monitor modePast trip record detained monitor mode How to set parameters Parameters for detailed and special setting. SeeWhen you adjust the inverter repeatedly using Same parameter. Parameter name CWJ. SeeHow to set the basic parameters ⇔HJ How to set extended parameters ~H Search and resetting of changed parameters I4W Example of parameter settingHow to search and reprogram parameters   ⇔ CEE How to use the history function Parameters that cannot be changed while running⇔CEE Returning all parameters to standard default setting How to save/load the user setting parametersKpkv Status monitor mode Monitoring the operation statusStatus monitor under normal conditions Iiii Pgtt ⇔ Display of detailed information on a past trip Display of trip information Trip code displayDisplay of trip information at the occurrence of a trip Example of call-up of trip informationOFF VIA VIB RES QR ⇔Cumulative E6581160 How to cope with the CE directive Measures to satisfy the standardsAbout the EMC directive Measures to satisfy the EMC directive Three-phase 500V class Example of wiring About the low-voltage directiveCompliance with Installation Compliance with UL Standard and CSA StandardMeasures to satisfy the low-voltage directive Compliance with ConnectionAIC, Fuse and Wire sizes Motor thermal protectionAIC a AWGTable of parameters and data User parametersBasic parameters Four navigation functionsCEE QNO Extended parameters Input/output parametersFrequency parameters   Operation mode parameters   Torque boost parameters Acceleration/deceleration time parameters Protection parameters  Output parameters Operation panel parametersCommunication parameters PM motor parameters Default settings by inverter rating XD/H       Table of input terminal functions AD2+SS3+AD2 , H, H, HTable of output terminal functions AD3,QJ,WR,GH,WE, On QE-,QR-,QJ,QN-,QNT Fcvibn Specifications Models and their standard specificationsStandard specifications Common specification CharacteristicsSpecification Outside dimensions and mass Outside dimensions and massOutline drawing VF-S11Fig.D Before making a service call Trip information and remedies Trip causes/warnings and remediesQNT   Industrial and Power Systems & Services Company