Toshiba VF-S11 manual Default settings by inverter rating, Xd/H       

Page 65

E6581160

QDefault settings by inverter rating

 

 

Inverter type

Torque boost

Dynamic

Dynamic

Automatic

Motor rated

Motor no-load

Motor

Over-voltage

 

 

braking

braking resistor

torgue boost

adjustment

stall protection

 

 

value 1/2

current

current

 

 

 

resistance

capacity

value

coefficient

level

 

 

 

 

 

 

 

 

 

XDH

H

H

H

H

H

H

H

 

 

 

(%)

(Ω) (Note)

(kW)

(%)

(A)

(%)

 

(%)

 

 

VFS11S-2002PL

6.0

200.0

0.12

8.3

1.2

70

90

134

 

 

VFS11S-2004PL

6.0

200.0

0.12

6.2

2.0

65

90

134

 

 

VFS11S-2007PL

6.0

200.0

0.12

5.8

3.4

60

80

134

 

 

VFS11S-2015PL

6.0

75.0

0.12

4.3

6.2

55

70

134

 

 

VFS11S-2022PL

5.0

75.0

0.12

4.1

8.9

52

70

134

 

 

VFS11-2002PM

6.0

200.0

0.12

8.3

1.2

70

90

134

 

 

VFS11-2004PM

6.0

200.0

0.12

6.2

2.0

65

90

134

 

 

VFS11-2005PM

6.0

200.0

0.12

6.0

2.7

62

80

134

 

 

VFS11-2007PM

6.0

200.0

0.12

5.8

3.4

60

80

134

 

 

VFS11-2015PM

6.0

75.0

0.12

4.3

6.2

55

70

134

 

 

VFS11-2022PM

5.0

75.0

0.12

4.1

8.9

52

70

134

 

 

VFS11-2037PM

5.0

40.0

0.12

3.4

14.8

48

70

134

 

 

VFS11-2055PM

4.0

20.0

0.24

3.0

21.0

46

70

134

 

 

VFS11-2075PM

3.0

15.0

0.44

2.5

28.2

43

70

134

 

 

VFS11-2110PM

2.0

10.0

0.66

2.3

40.6

41

60

134

 

 

VFS11-2150PM

2.0

7.5

0.88

2.0

54.6

38

50

134

7

 

VFS11-4004PL

6.0

200.0

0.12

6.2

1.0

65

90

140

 

 

 

 

VFS11-4007PL

6.0

200.0

0.12

5.8

1.7

60

80

140

 

 

VFS11-4015PL

6.0

200.0

0.12

4.3

3.1

55

70

140

 

 

VFS11-4022PL

5.0

200.0

0.12

4.1

4.5

52

70

140

 

 

VFS11-4037PL

5.0

160.0

0.12

3.4

7.4

48

70

140

 

 

VFS11-4055PL

4.0

80.0

0.24

2.6

10.5

46

70

140

 

 

VFS11-4075PL

3.0

60.0

0.44

2.3

14.1

43

70

140

 

 

VFS11-4110PL

2.0

40.0

0.66

2.2

20.3

41

60

140

 

 

VFS11-4150PL

2.0

30.0

0.88

1.9

27.3

38

50

140

 

 

VFS11-6007P

3.0

285.0

0.06

3.8

1.1

61

80

134

 

 

VFS11-6015P

3.0

145.0

0.12

3.8

2.1

59

70

134

 

 

VFS11-6022P

3.0

95.0

0.18

3.2

3.0

54

70

134

 

 

VFS11-6037P

3.0

48.0

0.37

3.5

4.9

50

70

134

 

 

VFS11-6055P

2.0

29.0

0.61

2.0

7.3

55

70

134

 

 

VFS11-6075P

2.0

29.0

0.61

1.5

9.5

51

70

134

 

 

VFS11-6110P

2.0

19.0

0.92

1.9

14.5

55

60

134

 

 

VFS11-6150P

1.0

14.0

1.23

1.7

19.3

53

50

134

Note: Be sure to set f308 (Dynamic braking resistance) at the resistance of the dynamic braking resistor connected.

64

Image 65
Contents Industrial Inverter For 3-phase induction motorsMeanings of symbols Safety precautionsSafety precautions Explanation of markingsGeneral Operation Wiring Transportation & installationOperations Maintenance and inspection When retry function is selected inverter Contents  Check product purchase Read firstCD-ROM E6581167 Installation Contents of the productConnection Standard connection diagramStandard connections VF-S11FLB FLCFLA PLC OUTSelection of wiring materials Power circuit terminalsPower circuit Description of terminalsControl circuit terminals SW1 Control circuit terminals24VDC PLC VIAFLB FLA PTCRY RC Slide switch SW1PLC Source Positive logic SW1 Source PLC Sink Simplified Operation of the VF-S11 OperationsEoqf HoqfStart and stop using the operation panel keys EOQF= How to start and stopCoast stop Example of operating a run from the panel How to set the frequencyHOQF= Frequency setting Setting the frequency using the operation panel HOQF= or Running and stopping using the operation panel How to operate the VF-S11Ex.2 Ex.3 Running and stopping using external signalsVIA Basic VF-S11 operations Status monitor mode Mode for monitoring all inverter statusPanel jog mode Past trip record detained monitor mode Flow of status monitor modeStandard monitor mode Parameters for detailed and special setting. See How to set parametersWhen you adjust the inverter repeatedly using Same parameter. Parameter name CWJ. See⇔HJ How to set the basic parameters ~H How to set extended parameters How to search and reprogram parameters Search and resetting of changed parameters I4WExample of parameter setting  ⇔ CEE  ⇔CEE How to use the history functionParameters that cannot be changed while running Kpkv Returning all parameters to standard default settingHow to save/load the user setting parameters Status monitor under normal conditions Status monitor modeMonitoring the operation status Iiii  Pgtt ⇔Display of detailed information on a past trip Trip code display Display of trip informationDisplay of trip information at the occurrence of a trip Example of call-up of trip informationQR ⇔ OFF VIA VIB RESCumulative E6581160 About the EMC directive How to cope with the CE directiveMeasures to satisfy the standards Measures to satisfy the EMC directive Three-phase 500V class About the low-voltage directive Example of wiringCompliance with UL Standard and CSA Standard Compliance with InstallationMeasures to satisfy the low-voltage directive Compliance with ConnectionMotor thermal protection AIC, Fuse and Wire sizesAIC a AWGUser parameters Table of parameters and dataBasic parameters Four navigation functionsCEE  QNOInput/output parameters Extended parametersFrequency parameters   Operation mode parameters   Torque boost parameters Protection parameters Acceleration/deceleration time parameters  Operation panel parameters Output parametersCommunication parameters PM motor parameters XD/H        Default settings by inverter ratingAD2 Table of input terminal functions, H, H, H +SS3+AD2AD3 Table of output terminal functionsQN-,QNT ,QJ,WR,GH,WE,On QE-,QR-,QJ, Fcvibn Standard specifications SpecificationsModels and their standard specifications Characteristics Common specificationSpecification Outside dimensions and mass Outside dimensions and massVF-S11 Outline drawingFig.D Trip causes/warnings and remedies Before making a service call Trip information and remediesQNT   Industrial and Power Systems & Services Company