E6581160
Ex.3 | Setting the operation frequency using |
running and stopping using external signals. | |
|
|
(1) | Wiring |
|
|
|
|
|
|
|
|
|
|
| PO | PA/+ | PB | PC/- |
|
|
|
| MCCB | R/L1 |
|
|
|
| U/T1 | Motor |
|
|
|
|
|
|
| 3 | |||
|
| * |
|
|
|
| |||
|
| S/L2 |
|
|
| V/T2 |
| ||
|
| Noise | Power circuit | IM | |||||
|
| T/L3 | filter | W/T3 | |||||
|
|
|
|
|
|
| |||
|
|
|
| Braking |
|
| F | Run forward |
|
|
|
|
| circuit |
|
| R | signal |
|
|
|
|
|
|
|
| Run |
| |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| backward |
|
|
|
|
|
|
|
|
| signal |
|
|
|
|
|
|
|
| CC | Common |
|
|
|
|
|
|
|
|
|
|
(2) | Parameter setting |
|
| |
| Title |
| Function | Programmed value |
| EOQF |
| Command mode selection | 0 |
| HOQF |
| Frequency setting mode selection | 0 |
(3) | Operation |
|
|
Run/stop: ON/OFF input to
Frequency setting: Set adjusting position of notches on the potentiometer.
* 600V models have no noise filter inside.
25