Toshiba VF-S11 Search and resetting of changed parameters I4W, Example of parameter setting

Page 33

E6581160

QExample of parameter setting

Steps in setting are as follows

(Example of changing the dynamic braking selection H from 0 to 1.)

 

 

Key operated

LED display

 

 

 

 

 

 

 

 

Operation

 

 

 

 

 

 

 

 

 

 

Displays the operation frequency (operation stopped).

 

 

 

 

 

 

 

 

 

.

(When standard monitor display selection H= [Operation

 

 

 

 

 

 

 

 

 

 

frequency])

 

 

 

 

 

MODE

 

 

 

CWJ

The first basic parameter “CWJ” (history function) is displayed.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

Press either the

 

or the

 

to change to the parameter group

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

Press the ENTER key to display the first extended parameter

 

 

 

 

 

 

 

 

 

H.

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

Press the

 

 

key to change to the dynamic braking selection H.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



Pressing the ENTER key allows the reading of parameter setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 



Press the

 

key to change the dynamic braking selection from  to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H

Pressing the ENTER key alternately flashes on and off the parameter

 

 

 

 

 

 

 

 

 

and changed value and allows the save of those values.

 

 

 

 

 

 

 

 

 

 

If there is anything you do not understand during this operation, press the MODE key several times to start over from the step of CWJ display.

For details on the function of each parameter, refer to the full version of English manual (E6581158).

4.2.3Search and resetting of changed parameters (I4W)

Automatically searches for only those parameters that are programmed with values different from the standard default setting and displays them in the user parameter group I4W. Parameter setting can also be changed within this group.

Notes on operation

If you reset a parameter to its factory default, the parameter will no longer appear in I4W.

fO, f470-f473 are not appeared, if the value of these parameters are changed.

QHow to search and reprogram parameters

The operations of search and resetting of parameters are as follows.

Key operated

LED display

Operation

 

 

 

 

Displays the operation frequency (operation stopped).

 

 

 



(When standard monitor display selection H= [Operation

 

 

 

 

frequency])

 

MODE

 

CWJ

The first basic parameter “CWJ” (history function) is displayed.

 

 

 

 

 

ITW

Press or key to select I4W.

32

Image 33
Contents Industrial Inverter For 3-phase induction motorsMeanings of symbols Safety precautionsSafety precautions Explanation of markingsGeneral Operation Wiring Transportation & installationOperations Maintenance and inspection When retry function is selected inverter Contents  Check product purchase Read firstCD-ROM E6581167 Installation Contents of the productConnection Standard connection diagramStandard connections VF-S11FLB FLCFLA PLC OUTSelection of wiring materials Power circuit terminalsPower circuit Description of terminalsControl circuit terminals SW1 Control circuit terminals24VDC PLC VIAFLB FLA PTCRY RC Slide switch SW1PLC Source Positive logic SW1 Source PLC Sink Simplified Operation of the VF-S11 OperationsEoqf HoqfStart and stop using the operation panel keys EOQF= How to start and stopCoast stop How to set the frequency HOQF=Example of operating a run from the panel Frequency setting Setting the frequency using the operation panel HOQF= or Running and stopping using the operation panel How to operate the VF-S11Ex.2 Ex.3 Running and stopping using external signalsVIA Status monitor mode Mode for monitoring all inverter status Panel jog modeBasic VF-S11 operations Flow of status monitor mode Standard monitor modePast trip record detained monitor mode Parameters for detailed and special setting. See How to set parametersWhen you adjust the inverter repeatedly using Same parameter. Parameter name CWJ. SeeHow to set the basic parameters ⇔HJ How to set extended parameters ~H Search and resetting of changed parameters I4W Example of parameter settingHow to search and reprogram parameters   ⇔ CEE How to use the history function Parameters that cannot be changed while running⇔CEE Returning all parameters to standard default setting How to save/load the user setting parametersKpkv Status monitor mode Monitoring the operation statusStatus monitor under normal conditions Iiii  Pgtt ⇔Display of detailed information on a past trip Trip code display Display of trip informationDisplay of trip information at the occurrence of a trip Example of call-up of trip informationQR ⇔ OFF VIA VIB RESCumulative E6581160 How to cope with the CE directive Measures to satisfy the standardsAbout the EMC directive Measures to satisfy the EMC directive Three-phase 500V class About the low-voltage directive Example of wiringCompliance with UL Standard and CSA Standard Compliance with InstallationMeasures to satisfy the low-voltage directive Compliance with ConnectionMotor thermal protection AIC, Fuse and Wire sizesAIC a AWGUser parameters Table of parameters and dataBasic parameters Four navigation functionsCEE  QNOInput/output parameters Extended parametersFrequency parameters   Operation mode parameters   Torque boost parameters Protection parameters Acceleration/deceleration time parameters  Operation panel parameters Output parametersCommunication parameters PM motor parameters XD/H        Default settings by inverter ratingAD2 Table of input terminal functions, H, H, H +SS3+AD2AD3 Table of output terminal functions,QJ,WR,GH,WE, On QE-,QR-,QJ,QN-,QNT Fcvibn Specifications Models and their standard specificationsStandard specifications Characteristics Common specificationSpecification Outside dimensions and mass Outside dimensions and massVF-S11 Outline drawingFig.D Trip causes/warnings and remedies Before making a service call Trip information and remediesQNT   Industrial and Power Systems & Services Company