| E6581160 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Communication |
|
| Minimum |
|
|
|
|
|
|
|
|
| Title | Function | Unit | setting unit | Adjustment range | Default | User |
| Reference |
| |||
| No. | Panel/Commun | setting | setting |
| E6581158 |
|
|
| ||||
|
|
|
|
|
|
| |||||||
|
|
|
|
| ication |
|
|
|
|
|
|
|
|
| H | 0307 | Supply voltage | - | - | 0: Supply voltage uncorrected, output | 2 |
|
| 6.13.6 |
|
|
|
|
|
| correction |
|
| voltage limited | (WP, WN) |
|
|
|
|
|
|
|
|
| (limitation of |
|
| 1: Supply voltage corrected, output | 3 (AN) |
|
|
|
|
|
|
|
|
| output voltage) |
|
| voltage limited |
|
|
|
|
|
|
|
|
|
|
|
|
| 2: Supply voltage uncorrected, output |
|
|
|
|
|
|
|
|
|
|
|
|
| voltage unlimited |
|
|
|
|
|
|
|
|
|
|
|
|
| 3: Supply voltage corrected, output |
|
|
|
|
|
|
|
|
|
|
|
|
| voltage unlimited |
|
|
|
|
|
|
|
| H | 0308 | Dynamic braking | Ω | 0.1/0.1 | * 1 |
|
| 6.13.4 |
|
|
| |
|
|
| resistance |
|
|
|
|
|
|
|
|
|
|
| H | 0309 | Dynamic braking | kW | 0.01/0.01 | * 1 |
|
| 6.13.4 |
|
|
| |
|
|
| resistor capacity |
|
|
|
|
|
|
|
|
|
|
| H | 0311 | - | - | 0: Forward/reverse run permitted | 0 |
|
| 6.13.7 |
|
|
| |
|
|
| prohibition |
|
| 1: Reverse run prohibited |
|
|
|
|
|
|
|
|
|
|
|
|
| 2: Forward run prohibited |
|
|
|
|
|
|
|
| H | 0312 | Random mode | - | - | 0: Disabled | 0 |
|
| 6.12 |
|
|
|
|
|
|
|
|
| 1: Automatic setting |
|
|
|
|
|
|
|
| H | 0316 | Carrier frequency | - | - | 0: Carrier frequency not reduced | 1 |
|
| 6.12 |
|
|
|
|
|
| control mode |
|
| automatically |
|
|
|
|
|
|
|
|
|
| selection |
|
| 1: Carrier frequency reduced |
|
|
|
|
|
|
|
|
|
|
|
|
| automatically |
|
|
|
|
|
|
|
|
|
|
|
|
| 2: Carrier frequency not reduced |
|
|
|
|
|
|
|
|
|
|
|
|
| automatically |
|
|
|
|
|
|
|
|
|
|
|
|
| Support for 500V/600V models |
|
|
|
|
|
|
|
|
|
|
|
|
| 3: Carrier frequency reduced |
|
|
|
|
|
| 7 |
|
|
|
|
|
| automatically |
|
|
|
|
|
| |
|
|
|
|
|
| Support for 500V/600V models |
|
|
|
|
| ||
| H | 0320 | Droop gain | % | 1/1 | 0 |
|
| 6.14 |
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| H | 0323 | Droop insensitive | % | 1/1 | 10 |
|
| 6.14 |
|
|
| |
|
|
| torque band |
|
|
|
|
|
|
|
|
|
|
| H | 0342 | Braking mode | - | - | 0: Disabled | 0 |
|
| 6.15 |
|
|
|
|
|
| selection |
|
| 1: Enabled (forward run) |
|
|
|
|
|
|
|
|
|
|
|
|
| 2: Enabled (reverse run) |
|
|
|
|
|
|
|
|
|
|
|
|
| 3: Enabled (operating direction) |
|
|
|
|
|
|
|
| H | 0343 | Release | Hz | 0.1/0.01 | 3.0 |
|
|
|
|
|
| |
|
|
| frequency |
|
|
|
|
|
|
|
|
|
|
| H | 0344 | Release time | s | 0.01/0.01 | 0.05 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| H | 0345 | Creeping | Hz | 0.1/0.01 |
| 3.0 |
|
|
|
|
|
|
|
|
| frequency |
|
|
|
|
|
|
|
|
|
|
| H | 0346 | Creeping time | s | 0.01/0.01 | 0.10 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| H | 0359 | PID control | s | 1/1 | 0 |
|
| 6.16 |
|
|
| |
|
|
| waiting time |
|
|
|
|
|
|
|
|
|
|
| H | 0360 | PID control | - | - | 0: Disabled, 1: Enabled | 0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| H | 0362 | Proportional gain | - | 0.01/0.01 | 0.30 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| H | 0363 | Integral gain | - | 0.01/0.01 | 0.20 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| H | 0366 | Differential gain | - | 0.01/0.01 | 0.00 |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
*1 : Default values vary depending on the capacity. See the table of 64.
57