Toshiba VF-S11 manual Frequency parameters

Page 55

 

 

 

 

 

 

 

 

 

 

 

E6581160

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Communication

 

 

Minimum

 

 

 

 

 

 

 

 

Title

Function

Unit

setting unit

Adjustment range

Default

User

 

Reference

 

 

 

No.

Panel/Commun

setting

setting

 

E6581158

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ication

 

 

 

 

 

 

 

 

H

0139

Output terminal

-

-

0: H and H

0

 

 

6.3.4

 

 

 

 

 

logic selection

 

 

H and H

 

 

 

 

 

 

 

 

 

(RY-RC, OUT-

 

 

1: H or H

 

 

 

 

 

 

 

 

 

NO)

 

 

H and H

 

 

 

 

 

 

 

 

 

 

 

 

2: H and H

 

 

 

 

 

 

 

 

 

 

 

 

H or H

 

 

 

 

 

 

 

 

 

 

 

 

3: H or H

 

 

 

 

 

 

 

 

 

 

 

 

H or H

 

 

 

 

 

 

 

H

0167

Frequency

Hz

0.1/0.01

0.0-HJ

2.5

 

 

6.3.5

 

 

 

 

 

command

 

 

 

 

 

 

 

 

 

 

 

 

agreement

 

 

 

 

 

 

 

 

 

 

 

 

detection range

 

 

 

 

 

 

 

 

 

 

H

0170

Base frequency 2

Hz

0.1/0.01

25.0-500.0

50.0 (WP)

 

 

6.4.1

 

 

 

 

 

 

 

 

 

60.0

 

 

 

 

 

 

 

 

 

 

 

 

(WN, AN)

 

 

 

 

 

 

H

0171

Base frequency

V

1/0.1

50-330 (240V class)

* 3

 

 

 

 

 

 

 

 

voltage 2

 

 

50-660 (500/600V class)

 

 

 

 

 

 

 

H

0172

Torque boost

%

0.1/0.1

0.0-30.0

* 1

 

 

 

 

 

 

 

 

value 2

 

 

 

 

 

 

 

 

 

 

H

0173

Motor electronic-

%

1/1

10-100

100

 

 

5.13

 

 

 

 

 

thermal protection

(A)

 

 

 

 

 

6.4.1

 

 

 

 

 

level 2

 

 

 

 

 

 

 

 

 

 

H

0185

Stall prevention

%

1/1

10-199,

150

 

 

6.4.1

 

 

 

 

 

level 2

(A)

 

200 (disabled)

 

 

 

6.19.2

7

 

 

*1 : Default values vary depending on the capacity. See the table of page 64.

 

 

 

 

 

 

*3 : 230 (240V class), 460 (500V class), 575 (600V class)

 

 

 

 

 

Frequency parameters

 

 

 

 

Minimum

 

 

 

 

Title

Communication

Function

Unit

setting unit

Adjustment range

Default

User

Reference

No.

Panel/Commun

setting

setting

E6581158

 

 

 

 

 

 

 

 

ication

 

 

 

 

H

0200

Frequency priority

-

-

0: HOQF (Switchable to H by

0

 

6.5.1

 

 

selection

 

 

terminal input)

 

 

7.1

 

 

 

 

 

1: HOQF (Switchable to H at

 

 

 

 

 

 

 

 

less than 1.0Hz of designated

 

 

 

 

 

 

 

 

frequency)

 

 

 

H

0201

VIA input point 1

%

1/1

0-100

0

 

6.5.2

 

 

setting

 

 

 

 

 

 

H

0202

VIA input point 1

Hz

0.1/0.01

0.0-500.0

0.0

 

 

 

 

frequency

 

 

 

 

 

 

H

0203

VIA input point 2

%

1/1

0-100

100

 

 

 

 

setting

 

 

 

 

 

 

H

0204

VIA input point 2

Hz

0.1/0.01

0.0-500.0

50.0 (WP)

 

 

 

 

frequency

 

 

 

60.0

 

 

 

 

 

 

 

 

(WN, AN)

 

 

H

0207

Frequency setting

-

-

0: Built-in potentiometer

1

 

6.3.5

 

 

mode

 

 

1: VIA

 

 

6.5.1

 

 

selection 2

 

 

2: VIB

 

 

7.1

 

 

 

 

 

3: Operation panel

 

 

 

 

 

 

 

 

4: Serial communication

 

 

 

 

 

 

 

 

5: UP/DOWN from external contact

 

 

 

 

 

 

 

 

6: VIA + VIB (Override)

 

 

 

54

Image 55
Contents Industrial Inverter For 3-phase induction motorsExplanation of markings Safety precautionsMeanings of symbols Safety precautionsGeneral Operation Wiring Transportation & installationOperations Maintenance and inspection When retry function is selected inverter Contents  Check product purchase Read firstCD-ROM E6581167 Installation Contents of the productVF-S11 Standard connection diagramConnection Standard connectionsPLC OUT FLCFLB FLADescription of terminals Power circuit terminalsSelection of wiring materials Power circuitControl circuit terminals VIA Control circuit terminalsSW1 24VDC PLCFLB FLA PTCRY RC Slide switch SW1PLC Source Positive logic SW1 Source PLC Sink Hoqf OperationsSimplified Operation of the VF-S11 Eoqf How to start and stopStart and stop using the operation panel keys EOQF= Coast stopHOQF= How to set the frequencyExample of operating a run from the panel Frequency setting Setting the frequency using the operation panel HOQF= or Running and stopping using the operation panel How to operate the VF-S11Ex.2 Ex.3 Running and stopping using external signalsVIA Panel jog mode Status monitor mode Mode for monitoring all inverter statusBasic VF-S11 operations Standard monitor mode Flow of status monitor modePast trip record detained monitor mode Same parameter. Parameter name CWJ. See How to set parametersParameters for detailed and special setting. See When you adjust the inverter repeatedly using How to set the basic parameters⇔HJ  How to set extended parameters~H Example of parameter setting Search and resetting of changed parameters I4WHow to search and reprogram parameters   ⇔ CEE Parameters that cannot be changed while running How to use the history function⇔CEE How to save/load the user setting parameters Returning all parameters to standard default settingKpkv Monitoring the operation status Status monitor modeStatus monitor under normal conditions Iiii  Pgtt ⇔Display of detailed information on a past trip Example of call-up of trip information Display of trip informationTrip code display Display of trip information at the occurrence of a tripQR ⇔ OFF VIA VIB RESCumulative E6581160 Measures to satisfy the standards How to cope with the CE directiveAbout the EMC directive Measures to satisfy the EMC directive Three-phase 500V class About the low-voltage directive Example of wiringCompliance with Connection Compliance with InstallationCompliance with UL Standard and CSA Standard Measures to satisfy the low-voltage directiveAWG AIC, Fuse and Wire sizesMotor thermal protection AIC aFour navigation functions Table of parameters and dataUser parameters Basic parametersCEE  QNOInput/output parameters Extended parametersFrequency parameters   Operation mode parameters   Torque boost parameters Protection parameters Acceleration/deceleration time parameters  Operation panel parameters Output parametersCommunication parameters PM motor parameters XD/H        Default settings by inverter ratingAD2 Table of input terminal functions, H, H, H +SS3+AD2AD3 Table of output terminal functionsOn QE-,QR-,QJ, ,QJ,WR,GH,WE,QN-,QNT Fcvibn Models and their standard specifications SpecificationsStandard specifications Characteristics Common specificationSpecification Outside dimensions and mass Outside dimensions and massVF-S11 Outline drawingFig.D Trip causes/warnings and remedies Before making a service call Trip information and remediesQNT   Industrial and Power Systems & Services Company