Manuals
/
Brands
/
Personal Care
/
Scale
/
A&D
/
Personal Care
/
Scale
A&D
GH-120/GH-200/GH-300/GH-202/GH-252 manual
Please, tick the box below to download manual:
Contents
Main
Analytical Balance
GH-120 GH-200 GH-300 GH-202 GH-252
Page
Contents
Page
1. Introduction
1.1. About This Manual
1.2. Features
1.3. Compliance 1.3.1. Compliance With FCC Rules
1.3.2. Compliance With EMC Directives
Page
2. Unpacking the Balance
2.1. Installing the Balance
3. Precautions
3.1. Before Use
3.2. During Use
3.3. After Use
3.4. Power Supply
4. Display Symbols and Key Operation
Display
Key operation
5. Weighing Units
5.1. Units
Page
Page
5.2. Changing the Units
5.2.1. Unit setting example
6. Weighing
Precautions for the weighing operation
6.1. Basic Operation (Gram Mode)
6.2. Dual Range
6.3. Counting Mode (PCS)
Selecting the counting mode
Storing a sample unit mass (Weighing input mode)
Counting operation
Counting mode using the ACAI function
6.4. Percent Mode (%)
Selecting the percent mode
Storing the 100% reference mass
Reading the percentage
7. Response Adjustment
7.1. Automatic Response Adjustment
7.2. Manual Response Adjustment
8. Calibration
8.1. Calibration Group
Calibration
Calibration test
Correction of the internal mass value
Automatic self calibration due to changes in temperature
Caution
8.3. One-Touch Calibration
8.4. Calibration Test Using the Internal Mass
8.5. Calibration Using an External Weight
8.6. Calibration Test Using an External Weight
8.7. Correcting the Internal Mass Value
9. Function Switch and Initialization
9.1. Permit or Inhibit
9.2. Initializing the Balance
10. Function Table
10.1. Setting the Function Table
Display symbol and keys
Setting procedure
Setting example
10.2. Details of the Function Table
Page
Page
10.3. Description of the Class "Environment, Display"
Condition ( Cond )
Stability band width ( 5t-b )
Zero tracking ( trc )
Display refresh rate ( 5pd )
Decimal point ( pnt )
Key mode
Auto print modes A and B
Auto print modes A
Auto print modes B
Stream mode
Interval memory mode
10.5. Description of the Item "Data Format"
A&D standard format 5if type 0
DP (Dump print) format 5if type 1
KF format 5if type 2
MT format 5if type 3
NU (numerical) format 5if type 4
CSV format 5if type 5
ID number dout 5-id 1
Data number dout d-no 1
Date dout 5-td 2 or 3
Time dout 5-td 1 or 3
Stable
Unstable
Overload
Units
10.7. Clock and Calendar Function
Operation
Confirming the time
Setting the time
Confirming the date
Setting the date
Quitting the operation
11. ID Number and GLP Report
11.1. Setting the ID Number
11.2. GLP Report
Calibration report using the internal mass
Calibration test report using an internal mass
Calibration report using an external weight
Calibration test report using an external weight
Title block and end block
12. Data Memory
12.1. Notes on Using Data Memory
Releasing "Clr" or "err"
12.2. Data Memory for Weighing Data
Storing the weighing data
Caution
Setting the function table
Enabling the data memory function
Recalling the memory data
Transmitting all memory data at one time
Deleting all memory data at one time
12.3. Data Memory for Calibration and Calibration Test
Storing the calibration and calibration test data
Transmitting the memory data
Deleting data stored in memory
13. Underhook
14. Density Measurement
Formula to obtain the density
Prior to measurement: Changing the function table
Entering the density of a liquid
Entering the water temperature (ldin 0)
The relation between the water temperature and density
Entering the density directly (ldin 1)
Measuring the density
15. Standard Input and Output Interface
15.1. RS-232C Interface
D-Sub 25 pin assignments
15.2. Connection to Peripheral Equipment
Connection to an AD-8121B printer
Connection to a computer and the use of WinCT
Using Windows Communication Tools Software (WinCT)
RsCom
RsKey
Using the WinCT software, the balance can do the following:
15.3. Commands 15.3.1. Command List
15.3.2. Acknowledge Code and Error Codes
15.3.3. Control Using CTS and RTS
Ct5 0
Ct5 1
15.3.4. Settings Related to RS-232C
15.3.5. Command Examples
ON command (turning on the balance)
R command (Re-zeroing the display)
CAL command (Calibration with internal mass)
Error code
Weighing with a tare
Setting a negative target value and filling with a sample until the display becomes zero
16. Maintenance
16.1. Treatment of the Balance
16.2. Error Codes
C
l
r
16.3. Other Display
16.4. Checking the Balance Performance and Environment
Checking that the operating environment or weighing method is proper
Operating environment
Weighing method
Sample and container
Checking that the balance performs properly
17. Specifications
17.1. External Dimensions
17.2. Options and Peripheral Equipment
GH-02 USB interface
GH-08 Ethernet Interface
AD-8121B Printer
AD-1653 Density Determination Kit
AD-1683 DC Static Eliminator
AX-USB-9P-EX USB Converter
AX-T-314A-S External key Plug
AX-SW128 Foot switch
Other options
18. Terms/Index
18.1. Terms
18.2. Index