Configuring a Remote Unit from the Central Site

3-9

example, if the central site unit is named “london”, then enter REM

london

If the tables are working correctly and the ISDN lines are functioning properly, then the Enter Password screen on the central site unit will be displayed. Go to step 8, below.

2If the Enter Password screen on the central site unit is not displayed within 30 seconds, Press [Ctrl]+[D] to return to the local unit management system screens.

3Press [Ctrl]+[V] to refresh the Remote Units screen.

4If the central site unit name and IP address are not listed, make a manual call of 5 minutes duration.

5Enter CALL followed by the central site number.

6While the call is up, press [Ctrl]+[V] at frequent intervals to refresh the Remote Units screen. When the central site unit name appears, cancel the manual call.

7Enter CANC followed by the central site number. Follow step 1 in this section for testing the IP Autocall and ISDN Number tables.

If the central site unit name is not listed on the Remote Units screen after 5 minutes, carefully check the configuration of both the remote and central site units. Ensure that IP routing has been enabled on both units.

8Enter QUIT to close the remote management session or press [Ctrl]+[D] if that command cannot be used.