3Com 980-000077/002 manual Configuring the Remote Unit, Assign the Unit Name

Models: 980-000077/002

1 78
Download 78 pages 20.48 Kb
Page 35
Image 35

Configuring a Remote Unit from the Central Site

3-13

Configuring the Remote Unit

Assign the Unit Name

1Enter CO SYS to display the System Parameters screen.

2Type in the name assigned to the unit in the Unit Name field. The name must be exactly the same as that used to configure the central site unit ISDN Numbers table.

Unit names are case-sensitive and must be entered correctly.

3Press [Ctrl]+[E] to submit the new setting and then enter SAVE

Configure the Ethernet Port

Changing the IP address during the remote management session causes the session to be disconnected when the new IP address is submitted. This is normal.

1Enter CO PO to display the Port Configuration screen.

2Select the LAN1 port using the Arrow keys and enter ED to display the Edit Ethernet Port screen.

3Type the IP address assigned to the unit in the Port IP Address field. The IP address must be exactly the same as that used to configure the central site unit ISDN Autocall table.

4Type a valid subnet mask for the network in the Port IP Mask field.

5Type a number between 6 and 10 in the Port Hop Count field. Increasing this setting from the default may help to prevent routing problems, in some cases.

6Press [Ctrl]+[E] to submit the new setting.

Submitting the IP address causes the remote management session to disconnect immediately.

7Press [Ctrl]+[D] to return to the central site unit management screens.

8Enter REM to display the Remote Units screen and press [Ctrl]+[V] to refresh the screen.

9Select the entry for the remote unit using the Arrow keys. Note that the entry now contains the remote unit name and IP address.