5-10 CHAPTER 5: NOVELL IPX ROUTING
CAUTION: Prior to despatch, it is essential that the unit has the ISDN Network Type field configured to match the ISDN network type at the remote site.
Prior to Despatch
Power on the unit and follow the sequence of steps for resetting the unit to the factory default configuration, as described in “Configuring a Central Site Unit for Routing IPX” on page
Configure the ISDN network type to the correct setting for the remote site, following the sequence of steps described in “Configure the ISDN Network Type” on page
When the unit is received at the remote site, ensure that it is powered on and that the ISDN Port is connected to a correctly functioning ISDN line, using the supplied ISDN cable.
Configuring the Central Site Unit
The central site unit must be correctly configured with the following parameters:
■Unit name (see page
■A valid IP address and subnet mask (see page
■The IPX network number (see page
■The IPX frame type (see page
■The correct ISDN network type (see page
An existing central site IPX router only requires IPX routing to be temporarily disabled and the remote site unit parameters to be added to the ISDN Numbers table, prior to configuring the remote unit.
Enable Novell RIP/SAP Learning
Novell RIP/SAP learning must be enabled at both ends of the link.
1Enter CO BR PA to display the Filter Parameters screen.
2Toggle the Learn Novell RIP/SAP field to ENABLE using the Spacebar.
3Press [Ctrl]+[E] to submit the new setting and then enter SAVE