Configuring a Remote Unit from the Central Site

4-11

7Press [Ctrl]+[E] to submit the new setting.

8Submitting the new settings causes the remote management session to disconnect immediately. This is normal.

9Press [Ctrl]+[D] to return to the central site unit management screens.

10If the Remote Units screen is not displayed, enter REM to display it.

The remote unit entry should now contain the remote unit name and IP address.

11Select the remote unit and enter REM

12Enter PASSWORD when the Enter Password screen is displayed.

13Enter SAVE to save the new configuration.

Configure the ISDN Numbers Table

Set up the ISDN numbers table to associate the central site unit name with its ISDN number.

1Enter CO IS NU to display the ISDN Numbers screen.

2Enter ADD to add a new entry to the ISDN Numbers table.

3Type the name assigned to the central site unit in the Name field and the ISDN number for that unit in the ISDN Number 1 field.

Do not alter the IP Address, IP Mask or IPX Network fields. Unit names are case-sensitive and must be entered correctly.

4Press [Ctrl]+[E] to submit the new setting and then enter SAVE

Enable NRIP/SAP Learning

RIP/SAP learning has to be enabled to allow the IPX Autocall table to be constructed.

1Enter CO BR PA to display the Filter Parameters screen. Toggle the Learn Novell RIP/SAP field to ENABLE using the Spacebar.

2Press [Ctrl]+[E] to submit the new setting and then enter SAVE