Chapter 8. Telnet/Terminal Menus
_____________________________Unit Access ____________________________
Unit ID | Passcode | Type | Polled | PollStatus |
20 | DEFAULT | Standard | No |
|
3 | 0033 | Standard | Yes | UP |
6 | 0095 | TSU Stand Alone | No |
|
8 | 0022 | Standard | Yes | UP |
1)Add New Unit
2)Modify Unit
3)Delete Unit
4) | Default Unit Passcode | 0022 |
5) | OK |
|
Figure 8-3. Unit Access Table
Add New Unit
This adds a new device to the unit access table.
•You must enter a device UNIT ID, PASSCODE, UNIT TYPE, and
POLLED FLAG.
•Unit type can be STANDARD (which supports any TSU/TDU Multiplexer and the ISU 512) or TSU STANDALONE (a single port TSU with no option card slot).
•You may select a passcode of 0 to 9999 for each device or DEFAULT. This results in the default passcode being used (defined as 0022 in Figure
•Traps are normally sent from the unit in alarm to the TSU 120. For units in the Unit Access Table that are not chained directly to the TSU 120 but are managed over Inband or the FDL, traps are not automatically forwarded.
•Polling must be enabled on the TSU 120 for these units in or- der to receive Traps on the NMS. The TSU 120 can be con- figured to poll selected units for traps by enabling the polled option when adding or modifying a unit entry.
TSU 120 User Manual |