Chapter 7. Test Menu

Port Test Menu Items for 0.1 Nx56/64

0.1Nx56/64 is the base Nx interface. It offers the following test functions:

DTE LOOPBK

This initiates a loopback. The following options are available:

PRT/LCL The Nx port activates both a Local loopback (back toward the DTE) and a Port loopback when either is invoked.

REMOTE The remote loopback causes a V.54 code to be sent to the far end. The Nx at the far end activates a PORT/LCL loopback upon detection of the V.54 code.

OFF

The loop is deactivated.

The TSU 120 checks the remote loopback activation by detecting a proper response from the remote end. While waiting for the re- sponse, the display shows Looping. If successful, the display changes to LOOPED-UP. If unsuccessful, the display shows FAILED.

511 PATTERN

This activates the generation of the 511 test pattern. The follow- ing options are available:

ON

The pattern check circuitry is enabled and a

 

test started. The test is ended by selecting

 

OFF.

OFF

The pattern generation and check is

 

disabled.

511 RESULTS

 

This displays the results of the 511 test indicated in the 511 option. The results are in the form of the number of errored sec- onds. The error count can be cleared by pressing Clear (Shift+9).