SET LBO

Selects the line build out for the network interface. In

 

 

AUTO MODE, the TSU 120 sets the LBO based on the

 

 

strength of the receive signal and displays the selected

 

 

value.

 

 

Choices: 0.0 dB, 7.5 dB, 15 dB, 22 dB, Auto.

 

 

In order to activate the -36 dB receiver sensitivity, the

 

 

LBO should be set to AUTO.

 

 

This feature is useful in a point-to-point application

 

 

where no network elements are involved. If a network

 

 

element such as a Smart Jack is installed on the circuit,

 

 

the LBO should be set to 0 dB.

 

 

 

 

INBAND

Sets unit to accept or reject the network interface loop-

 

LPBCK

up and loop-down codes as defined in ANSI T1.403.

 

 

Choices: Accept, Reject.

 

 

 

 

BIT

When enabled, bit stuffing causes the TSU 120 to

 

STUFFING

monitor for ones (1s) density violations and insert a one

 

 

(1) when needed to maintain 1s at 12.5 percent.

 

 

Choices: Enable, Disable.

 

 

 

 

TR-08

The TR-08 submenu configures the unit for TR-08

 

 

applications. The submenu items and their descriptions

 

 

follow.

 

 

Alarm Report

 

 

Enables and disables the transmitting of alarm reports.

 

 

Choices: SEND ALARMS, DISABLE ALARMS

 

 

Alarm Format

 

 

Sets the alarm frame format to 13 frames or 16 frames.

 

 

Choices: ORB-13, ORB-16

 

 

BPV Threshold

 

 

Sets the threshold for BPVs to trigger an alarm.

 

 

Choices: 10-4, 10-5, 10-6

 

 

 

 

 

 